iQ Control Box
01.25.2019
1.800.7.ACCESS • www.stanleyaccess.com • Document # 204144 REV B 35
Cop
yr
ight 2019, S
tanley Ac
cess T
echnologies, LL
C. All rights r
es
er
ved. R
epr
oduction
in whole or in p
ar
t without the expr
ess wr
itt
en permission o
f S
tanley is pr
ohibit
ed.
Attachment 5
Troubleshooting Aid (Sheet 1 of 1)
Terminal and Pin
Description
State
TB1-8
Solenoid Lock Output
Dark = Unlocked
w/o PCB, fail secure
Dark = Unlocked
w/o PCB, fail safe
Dark = Locked
Rotary Function Switch States for TB2
Hold
Open
Closed
Locked
Automatic
One Way
Reduced
Reduced
One Way
TB2-1
TB2-3
TB2-5
Don’t Care
Don’t Care
TB2-7
Rocker Function Switch States for TB2
Hold
Open
Closed
Locked
Automatic
One Way
Reduced
Reduced
One Way
TB2-1
TB2-3
TB2-5
Don’t Care
Don’t Care
TB2-7
Don’t Care
Don’t Care
Terminal and Pin
Description
State
TB3-4
Stanguard
TM
Input/Output
Dark = triggered or detecting
TB3-8 & TB4-8
Non-Monitored Holding Beam Input Input
and Outside Sensor (connected internally)
Dark = detecting
TB3-9
Breakout Input
Dark = no breakout
TB4-4 & TB4-9
Inside Sensor Input and
Push Plate Input (connected internally)
Dark = detecting
TB4-8 & TB3-8
Inside Presence Sensor Input and
Holding Beam Input (connected internally)
Dark = detecting
TB4-9 & TB4-4
Push Plate Input and
Inside Sensor Input (connected internally)
Dark = detecting
TB5-3
Side Screen Sensor Input
Dark = detecting
TB5-7
Closed-Door Position Switch Input
Dark = closed
TB5-10
Spare
TB6-1
Monitored Beam Upper Holding Beam
Dark = unobstructed White = detecting
TB6-3
Monitored Beam Lower Holding Beam
Dark = unobstructed White = detecting
TB6-5
Photo Beam Pro Test Output
Dark = testing
TB6-7
Sensor Test Output
Dark = normal operation
NOTE
: Black color indicates a low signal (Approx. 0 VDC).