iQ Control Box
16 Document # 204144 REV B • www.stanleyaccess.com • 1.800.7.ACCESS
Cop
yr
ight 2019, S
tanley Ac
cess T
echnologies, LL
C.
All rights r
es
er
ved. R
epr
oduction
in whole or in p
ar
t without the expr
ess wr
itt
en permission o
f S
tanley is pr
ohibit
ed.
01.25.2019
Index
Min
Value
Max
Value
Description
Defaults
Single
Dual
48
0
3
IO configuration
0
0
TB2-5
TB2-7
TB2-9
00
(Default)
1 way / 2 way Reduced
Access Control Pro activation override (highest priority
when selected).
4 Monitored Sensors (when selected).
Delay egress reset (default).
01
1 way / 2 way Reduced
Fire Alarm.
02
1 way / 2 way Fire alarm Access Control Pro activation override (highest priority
when selected).
4 Monitored Sensors (when selected).
Delay egress reset (default).
03
Fire alarm
Reduced
Access Control Pro activation override (highest priority
when selected).
4 Monitored Sensors (when selected).
Delay egress reset (default).
IO Configuration Parameter Description
Allows the Fire Alarm to be used instead of functions normally used with the selected input:
0 = Standard Functions (NO Fire Alarm Input).
1 = Fire Alarm Input is TB2-9 (Removes Functions: Access Control Pro activation override, Delayed Egress Reset,
and 4 Monitored Sensor capability).
2 = Fire Alarm Input is TB2-7 (Removes Reduced Open function).
3 = Fire Alarm Input is TB2-5 (Removes One-way function).
Index
Min
Value
Max
Value
Descriptions
Defaults
Single
Dual
49
0
99
Open Power
Assist Torque
This parameter sets the current to the motor which
is used to make the door feel easier to move open
when in “Manual” mode. This value should be
set only as high as is needed to reduce the force
required to move the door. Setting this value too
high can cause the door to move by itself.
Only available when index 11 is set to 02-ICU.
60
60
50
0
99
Close Power
Assist Torque
This parameter sets the current to the motor which
is used to make the door feel easier to move closed
when in “Manual” mode. This value should be
set only as high as is needed to reduce the force
required to move the door. Setting this value too
high can cause the door to move by itself.
Only available when index 11 is set to 02-ICU.
50
50
Table 3. Settings (continued)