Index
Min
Value
Max Value
Description
Defaults
Single
Dual
15
1
10
Open
Braking
The Open Braking parameter adjusts
how quickly the door slows down prior
to check speed.
Increasing this parameter increases
braking power.
8
8
16
0
40
Close
Acceleration
Close Acceleration affects the rate at
which the door gets to its target speed.
This parameter is used when the door is
lagging close speed, close startup torque
and close startup length should be
investigated prior to increasing.
This parameter affects all close motion
speeds: close speed, close check speed,
close learn speed, as well as close
braking.
20
20
17
1
10
Close
Braking
The Close Braking parameter adjusts
how quickly the door slows down prior
to check speed.
Increasing this parameter increases
braking power.
4
2
18
0
6
Delayed Egress
Special Locking Application. See the
Delay Egress Instruction Manual for use.
00 = Off
01 = 15 sec delay 1 second nuisance
02 = 30 sec delay 1 second nuisance
03 = 15 sec delay 2 second nuisance
04 = 30 sec delay 2 second nuisance
05 = 15 sec delay 3 second nuisance
06 = 30 sec delay 3 second nuisance
0
0
19
0
5
Safety Logic
00 - Monitored 2 Sensors: Threshold
zone control (the threshold zone
is enabled and disabled by the iQ).
1 - Monitored 4 Sensors: Threshold
zone control (the threshold zone is
enabled and disabled by the iQ).
2 - Monitored StanGuard™: (not
recommended for Telescopic doors).
3 - Monitored 2 sensors.
4 - Non-monitored sensors.
5 - Monitored 4 sensors.
2
2
Table 3. Settings (continued)
Table 3 Settings continued next page.