iQ Control Box
01.25.2019
1.800.7.ACCESS • www.stanleyaccess.com • Document # 204144 REV B 5
Cop
yr
ight 2019, S
tanley Ac
cess T
echnologies, LL
C. All rights r
es
er
ved. R
epr
oduction
in whole or in p
ar
t without the expr
ess wr
itt
en permission o
f S
tanley is pr
ohibit
ed.
3.
Solenoid Lock
: If a solenoid lock is installed with no lock circuit board (new style), set Lock Logic to the
actual lock type (Fail Safe or Fail Secure). If a Fail Safe or Fail Secure Lock is being installed with a lock circuit
board (old style), the Lock Logic must be set to Fail Secure.
4.
Handing (For purpose of FIS only)
: Manually open door noting rotation of belt pulleys. If counter clockwise (CCW)
use right hand during FIS. If clockwise (CW) use left hand during FIS. See figure below.
5
. FIS
: The first installation sequence (FIS) is used to perform the initial configuration. Upon completion of FIS, all
setup parameters are stored in non-volatile memory. Subsequent power cycles will reload the
configuration parameters that were configured during FIS.
6. Decimal points on digital display are encoder 1 signals. Rotating motor will cause decimal points to blink
and appear to dim.
7. After changing values, the values must be saved in non-volatile memory by cycling the door to full open.
PULLEY ROTATES CCW
WHILE OPENING
USE RIGHT HAND IN FIS
PULLEY ROTATES CW
WHILE OPENING
USE LEFT HAND IN FIS
RIGHT HAND
LEFT HAND
HANDING