Attachment 4
ANSI/BHMA and IBC Compliance Requirements for
Low Energy
Power Operated Sliding Doors
(Sheet 3 of 3)
To ensure that a
Low Energy
Power Operated Sliding Door operates in accordance with ANSI/BHMA and the
the IBC-2018, the following must be established:
• Activation of the door must be by a
Knowing Act
.
• The Opening Time (speed) of the Door(s) shall be adjusted so that the door(s) open at a speed of
12 inches
per second maximum
, from fully closed to fully open.
• When powered open, the door shall remain at the fully open position for not less than 5 seconds before
starting the closing cycle.
• The Closing Time (speed) of Door(s) shall be adjusted so that the door(s) close at a speed of
6 inches per
second maximum
per leaf, from fully open to latch check.
• Latch check shall occur at no less than 2 inches from fully closed.
•
The
force
required to prevent a stopped door from opening or closing shall not exceed 15 lbf (67 N).
•
The required Signage must be present
.
NOTE
: In special applications where safety sensors or secondary activation sensors are used on
a low energy door, refer to ANSI/BHMA A156.10 for guidance on sensor performance criteria
for the type of sensor selected.