Fine Tuning Slide Doors
(Sheet 1 of 2)
Tuning the Stanley Automatic Door
Match your actual door to one from the list of doors described in the attachment. Start by installing these settings.
Use the guide below to make adjustments to these settings.
If the door:
OPENS TOO SLOWLY
If it is too slow
If it is too slow
Increase
Open Speed
. Maximum setting is 99 with keypad or
125 with handheld.
Increase
Open Torque
Increase
Open Acceleration
NOTES
:
Max Values go to 125 via handheld.
Open Torque
is also used to set the door open force.
HITS THE OPEN STOP
Increase
Open Stop
to 8 and
Open Check Length
to 45
Increase
Open Brake
until there is good braking.
Increase or decrease until there is good motion
entering and in
Open Check
.
When the door braking and motion are under control, reduce the
Open Check
length as desired.
CLOSES TOO SLOWLY
If it is too slow
If it is too slow
Increase
Close Speed
to 16
Increase
Close Torque
Increase
Close Acceleration
NOTE
:
Close Torque
is also used to set the door closing force.
Close Speed
and
Close Force
cannot exceed the value specified by ANSI/BHMA 156.10.