![Stange SE-707 Operating Manual Download Page 158](http://html.mh-extra.com/html/stange/se-707/se-707_operating-manual_1359472158.webp)
Program Controller SE-707
© 2018 by STANGE Elektronik GmbH
158
Subject to technical modifications
PLC example for triggering the data logger
Select and release time cycle 1:
L
FI
964
If time cycle 2 is active
R
FI
964
then reset for time cycle selection 1 is active
LN
FI
965
If release time cycle is not active
S
FI
965
the set release time cycle active
Evaluation for process start: Start data recording (triggered by start key on the programmer page):
L
FO
1311
If process start (triggered by start button)
=
FI
961
then batch recording start
The programmer start takes place after 5 seconds in this example in order to clarify that the data recording may also contain a possibly
preparation phase for the real program start:
L
FO
1311
If process start (triggered by start button)
A
FO
1305
and if batch recording is active
S
TN
1
then after 5 seconds
L
CS
5
L
TN
1
=
FI
809
Start of the programmer
Take back process start as soon as the programmer is active:
L
FO
768
Programmer active
R
FO
1311
Process start reset
Monitoring for the end of data recording and then, in this example, terminate data recording after 5 seconds:
L
FO
1305
If batch recording active
AN
FO
1311
and not process start
AN
FO
768
and programmer not active:
S
TN
2
then after 5 seconds
L
CS
5
L
TN
2
=
FI
962
Trigger off batch end