33
Batteries are dead in Power
Meter
Insert new batteries in Power Meter and Pair if
necessary
Power Meter needs to be
rebooted
Open battery door and reverse batteries in Power Meter,
close battery door for 3 seconds, (this will reboot Power
Meter) and then re-insert batteries properly into Power
Meter and retest. Re-pair if necessary
Ant + number from Power Meter in
console is not correct
Insert proper Ant + number in console and Re- Pair
Console will not Zero Reset
Power Meter not awake enough
Apply ample pressure and spin power meter enough that
it is awake
Load was on Power Meter when
been being Zero Reset
Take load off of Power Meter and retry
Battery Door Broke
Check for breaks in battery door, order parts if needed
Power Meter needs to be
rebooted
Open battery door and reverse batteries in Power
Meter, close battery door for 3 seconds, (this will
reboot Power Meter) and then re-insert batteries
properly into Power Meter and retest. Re-pair if
necessary