16
PAIRING (AND INTERNAL ZERO RESET)
SUMMARY:
This section provides information on how to perform the pairing (and internal reset) of the console and power meter on
your bike(s). This section applies to the Stages SC3.18 Indoor Cycling bikes that have a console and power meter installed.
Note: This
procedure should only be performed when installing a new console, power meter (or both), but should not be used on a routine basis
to zero reset the bike. For steps to reset on a routine basis, reference the External Zero Reset section in this SOP.
DETAILS:
Pairing Steps:
1.
Activate the console by pressing any button
(BACKLIGHT, STAGE or SETTINGS).
2.
Press and hold the BACKLIGHT and AVG/END buttons
for five seconds to enter the SETTINGS menu.
3.
Use the AVG/END button to advance the settings menu
and press the STAGE button to enter PAIRING.
4.
Press the STAGE button to enter PWR METER.
5.
Press the STAGE button to enter ANT+ ID.
6.
Press the STAGE button to enter ANT.
7.
Locate the ANT+ ID on the sticker attached to the power
meter (left crank arm).
Note: The ANT+ ID will be a 4-5 digit
ID number that appears in several stickers applied to the
crank arm.
8.
Enter the ANT+ ID from the power meter that is on the
bike, into the console by using the BACKLIGHT button to
advance the digit to number required (numbers will increase
from 0-9 and return to 0).
Note: If you have a 4 digit number
on your crank sticker, insert a 0 in the first position of the
console when entering your ANT+ ID number. The pairing
process can be done on multiple bikes at the same time, as
they are being directly paired by their own individual ANT+
ID.
9.
Press the AVG/END button to select the number and move to
the next number. The highlight will move from left to right and
then return to the first digit.
10.
After you have entered all of the numbers into the console
that match the ANT+ ID number from power meter, press the
STAGE button to begin pairing and spin the power meter on the
bike.
Note: You must crank the power meter really hard, (with
your leg) with force or the pairing process may fail.
11.
If the pairing process is successful, the word PAIRED will
appear in the message banner. If FAILED appears on the screen,
make sure that you have entered all of the correct numbers of the
ANT+ ID into the console and try again. Once paired, the console
and power meter will remain paired unless it is paired to another.
Note: If it continues to fail, look at trouble shooting option.
Pairing the power meter only needs to be performed on a new
console upon installation. Once paired, the console will remain
attached to that specific power meter.
12.
After the console is paired to the power meter, the words
ZERO RESET will be displayed on the screen.
13.
Place the power meter in the 6 o'clock position.
14.
With
NO
weight (feet or outside force) on the left pedal,
press the STAGE button to begin the zero reset process. After
pressing the STAGE button, you will see dashes moving across
the bottom right side of the console, indicating that the Zero
Reset process is taking place.
15.
The Zero Reset process will take a few seconds. If the Zero
Reset was performed correctly, you will see the word SUCCESS
and a numerical calculation on the screen will appear. The
number should be between 790 and 990. If it is not within this
range, try and reset. If the word FAILED appears on the screen,
don’t be alarmed. Ensure that the crank was in the 6 o’clock
position and NO weight is on the pedal and try again
.
Note: If it
continues to fail, reference trouble shooting area.