background image

Please unfold page 3. Then you will always see the

operating elements and connections described.

1

Operating Elements and Connections

1.1 Rear panel

1

Locking screws for the mounting bracket (2)

2

Mounting bracket

3

DMX signal input (3-pole, XLR);

1 = ground, 2 = DMX-, 3 = DMX+

4

DMX signal output (3-pole, XLR) for connection to

the DMX input of another DMX light effect unit;

1 = ground, 2 = DMX-, 3 = DMX+

5

Mains cable for connection to a socket (230 V~/

50 Hz)

6

Support for the mains fuse

Always replace a fuse that has blown by one of the

same type.

7

DIP switches (Nos. 1 to 9) for adjusting the DMX

start address

8

LED; will flash when a DMX control signal is re-

ceived or will flash to the beat of the music

9

Connection jack for the remote control LC-3

10

Button for activating the automatic address as-

signment

1.2 Remote control LC-3

The remote control is available as an accessory and

not supplied with the LED spotlight.

11

Button STAND BY for the function Blackout (light

off)

12

Button FUNCTION for selecting various light

changing functions depending on the operating

mode selected with the button MODE

13

Button MODE for switching over between

Sound mode 1

(LED off)

Manual mode

(LED on)

Sound mode 2

(LED flashing slowly)

Auto mode

(LED flashing rapidly)

Note: For control via the remote control, there must be

no DMX signal at the DMX INPUT (3).

2

Safety Notes

The spotlight corresponds to all required directives of

the EU and is therefore marked with .

Please observe the following items in any case:

G

The spotlight is suitable for indoor use only. Protect

it against dripping water and splash water, high air

humidity, and heat (admissible ambient temperature

range 0 – 40 °C).

G

Do not operate the spotlight or immediately discon-

nect the mains plug from the mains socket

1. in case of visible damage to the unit or to the

mains cable,

2. if a defect might have occurred after the unit was

dropped or suffered a similar accident,

3. if malfunctions occur.

In any case the unit must be repaired by skilled per-

sonnel.

G

A damaged mains cable must be replaced by skilled

personnel only.

G

Never pull the mains cable for disconnecting the

mains plug from the mains socket, always seize the

plug.

G

For cleaning only use a dry, soft cloth, never use

chemicals or water.

G

No guarantee claims for the spotlight and no liability

for any resulting personal damage or material

damage will be accepted if the spotlight is used for

other purposes than originally intended, if it is not

safely mounted or correctly operated, or not repaired

in an expert way.

G

Important for U. K. Customers!

The wires in this mains lead are coloured in accord-

ance with the following code:

green/yellow = earth

blue = neutral

brown = live

As the colours of the wires in the mains lead of this

appliance may not correspond with the coloured

markings identifying the terminals in your plug, pro-

ceed as follows:

1. The wire which is coloured green and yellow must

be connected to the terminal in the plug which is

marked with the letter E or by the earth symbol ,

or coloured green or green and yellow.

2. The wire which is coloured blue must be con-

nected to the terminal which is marked with the

letter N or coloured black.

3. The wire which is coloured brown must be con-

nected to the terminal which is marked with the

letter L or coloured red.

Warning – This appliance must be earthed.

If the spotlight is to be put out of operation

definitively, take it to a local recycling plant for

a disposal which is not harmful to the envi-

ronment.

WARNING

The spotlight is supplied with hazardous

mains voltage (230 V~). Leave servic-

ing to skilled personnel only and do not

insert anything into the air vents, other-

wise you will risk an electric shock!

8

GB

Summary of Contents for PARL-56PDX/CR

Page 1: ...AL DE INSTRUCCIONES INSTRUKCJA OBS UGI SIKKERHEDSOPLYSNINGER S KERHETSF RESKRIFTER TURVALLISUUDESTA DMX LED SCHEINWERFER DMX LED SPOTLIGHT PROJECTEUR DMX LEDs FARETTO DMX A LED PARL 56PDX CR Best Nr 3...

Page 2: ...recchio di img Stage Line Leggete attentamente le istruzioni prima di mettere in fun zione l apparecchio Solo cos potete conoscere tutte le funzionalit evitare comandi sbagliati e proteggere voi stess...

Page 3: ...3 1 2 4 8 16 32 64 128 256 No Function 10 9 8 7 6 5 4 3 2 1 DIP ON F USE FUSE ONLY FOR REMOTE CONTROL DMX ADDRESS SETTING DMX INPUT DMX OUTPUT 2 1 3 1 2 3 1 2 3 4 1 5 6 7 8 9 10 11 12 13...

Page 4: ...ssiger Einsatztemperaturbereich 0 40 C G Nehmen Sie den Scheinwerfer nicht in Betrieb oder ziehen Sie sofort den Netzstecker aus der Steckdose 1 wenn sichtbare Sch den am Ger t oder an der Netzanschl...

Page 5: ...tage Line mit dem Anschluss DMX INPUT 3 des ersten Nebenger tes verbinden Den Anschluss DMX OUTPUT des ersten Neben ger tes mit dem Anschluss DMX INPUT des zweiten Nebenger tes verbinden usw 6 2 Fernb...

Page 6: ...entspre chenden Abschlussstecker z B DLT 123 von img Stage Line verwenden 7 2 Startadresse einstellen Um den Scheinwerfer mit einem Lichtsteuerger t bedienen zu k nnen muss die DMX Startadresse f r de...

Page 7: ...5 9 13 max 61 einstel len Kapitel 7 2 Genaueres zur Bedienung ent nehmen Sie bitte der Anleitung zum LED 4C 8 Technische Daten Stromversorgung 230 V 50 Hz Leistungsaufnahme 20 VA Leuchtmittel PARL 56P...

Page 8: ...ains socket 1 in case of visible damage to the unit or to the mains cable 2 if a defect might have occurred after the unit was dropped or suffered a similar accident 3 if malfunctions occur In any cas...

Page 9: ...several spotlights Several PARL 56PDX and PARL 64PDX units also a combination of both may be interconnected in order to change colours in sync or to control all slave units to the same rhythm via the...

Page 10: ...the DMX output or use a corre sponding terminating plug e g DLT 123 by img Stage Line 7 2 Adjusting the start address For operation of the spotlight with a light controller adjust the DMX start addres...

Page 11: ...LEDs red 50 green 53 blue 53 PARL 64PDX 212 extra bright 5 mm LEDs red 70 green 71 blue 71 Beam angle 40 Ambient temperature 0 40 C Dimensions PARL 56PDX 190 mm 185 mm PARL 64PDX 216 mm 205 mm Weight...

Page 12: ...40 C G Ne faites pas fonctionner le projecteur ou d bran chez le imm diatement du secteur lorsque 1 des dommages visibles apparaissent sur l appa reil ou sur le cordon secteur 2 apr s une chute ou un...

Page 13: ...ier appareil auxi liaire Reliez la connexion DMX OUTPUT du premier appareil auxiliaire la connexion DMX INPUT du deuxi me appareil auxiliaire et ainsi de suite 6 2 T l commande LC 3 Via la t l command...

Page 14: ...iche dans la sortie DMX ou uti lisez un bouchon correspondant p ex DLT 123 de img Stage Line 7 2 R glage de l adresse de d marrage Pour pouvoir utiliser le projecteur avec un contr leur il faut r gler...

Page 15: ...1 max voir chapitre 7 2 Reportez vous la notice du LED 4C pour plus de d tails 8 Caract ristiques techniques Alimentation 230 V 50 Hz Consommation 20 VA Lampes PARL 56PDX 156 LEDs 5 mm extr me ment cl...

Page 16: ...a alta umidit dell aria e dal calore temperatura d im piego ammessa fra 0 e 40 C G Non mettere in funzione il faretto e staccare subito la spina rete se 1 l apparecchio o il cavo rete presentano dei d...

Page 17: ...ecc 6 2 Telecomando tramite LC 3 Per mezzo del telecomando LC 3 disponibile come accessorio possibile comandare diverse funzioni oltre al comando tramite la musica 1 Collegare il telecomando con la p...

Page 18: ...l indirizzo di start Per poter usare il faretto con un unit di comando luce occorre impostare l indirizzo di start DMX per il primo canale DMX Se per esempio sull unit di comando previsto l indirizzo...

Page 19: ...dirizzo di start dei faretti su 1 o su un multiplo di 4 1 5 9 13 max 61 Capi tolo 7 2 Delle indicazioni pi particolari sul funziona mento si trovano nelle istruzioni del LED 4C 8 Dati tecnici Alimenta...

Page 20: ...mijd druip en spatwater plaatsen met een hoge vochtigheid en uitzonderlijk warme plaatsen toegestaan omgevingstemperatuurbereik 0 40 C G Schakel de schijnwerper niet in of trek onmiddellijk de stekker...

Page 21: ...het eerste randapparaat Verbind de aansluiting DMX OUTPUT van het eerste randapparaat met de aansluiting DMX INPUT van het tweede randapparaat etc 6 2 Afstandsbediening via LC 3 Via de als toebehoren...

Page 22: ...en lichtregelaar te kunnen bedienen moet het DMX startadres voor het 1ste DMX kanaal worden ingesteld Als bijvoorbeeld op de regeleenheid het adres 17 voorzien is voor het bestu ren van de rode kleur...

Page 23: ...max 61 in hoofdstuk 7 2 Meer gedetailleerde informatie vindt u terug in de handleiding LED 4C 8 Technische gegevens Voedingsspanning 230 V 50 Hz Vermogensverbruik 20 VA Verlichting PARL 56PDX 156 sup...

Page 24: ...l aire y calor temperatura ambiente admisible 0 40 C G No utilice el proyector o desconecte el enchufe de la toma de corriente 1 En caso de da o visible en el aparato o en el cable de corriente 2 Si s...

Page 25: ...TPUT de la primera uni dad secundaria a la entrada DMX INPUT de la segunda y as sucesivamente 6 2 Control remoto LC 3 El control remoto LC 3 disponible como accesorio permite controlar varias funcione...

Page 26: ...cci n de inicio Para el funcionamiento del proyector con un controla dor de luces ajuste la direcci n DMX de inicio para el primer canal DMX Si p ej la direcci n 17 del contro lador es para controlar...

Page 27: ...o 7 2 Puede encontrar informaci n deta llada para el funcionamiento en el manual del LED 4C 8 Especificaciones Alimentaci n 230 V 50 Hz Consumo 20 VA Iluminaci n PARL 56PDX 156 LEDs de 5 mm de gran br...

Page 28: ...nale y w cza lub natychmiast od czy urz dzenie od sieci w przypadku 1 gdy stwierdzono widoczne uszkodzenie urz dze nia lub kabla zasilaj cego 2 je li urz dzenie mog o ulec uszkodzeniu na sku tek upad...

Page 29: ...ji 1 Pod czy pilot do gniazda REMOTE CONTROL 9 2 Na wej cie DMX INPUT 3 urz dzenia nie mo e by podawany w tym czasie aden sygna 3 Po pod czeniu na wyj cie DMX OUTPUT 4 kolejne urz dzenia podrz dne PAR...

Page 30: ...tan przypisane automatycznie kolejne trzy adresy w tym przypadku 18 do 20 Jako adres startowy kolejnego urz dzenia mo na w wczas ustawi 21 Istniej trzy metody ustawiania adresu 7 2 1 Automatyczne usta...

Page 31: ...ie 53 PARL 64PDX 212 super jasnych 5 mm diod czerwone 70 zielone 71 niebieskie 71 K t wiecenia 40 Zakres temperatur 0 40 C Wymiary PARL 56PDX 190 mm 185 mm PARL 64PDX 216 mm 205 mm Waga PARL 56PDX 2 5...

Page 32: ...tation for bortskaffelse ADVARSEL Enheden benytter livsfarlig netsp nding 230 V For at undg fare for elektrisk st d m kabinettet ikke bnes Overlad servicering til autoriseret personel DMX LED Str lkas...

Page 33: ...n irrota virtajohtoa pistorasiasta johdosta vet m ll G K yt puhdistamiseen pelk st n kuivaa pehme kangasta l k yt kemikaaleja tai vett G Laitteen takuu raukeaa eik valmistaja maahan tuoja tai myyj ota...

Page 34: ...Copyright by MONACOR INTERNATIONAL GmbH Co KG Bremen Germany All rights reserved A 0798 99 02 04 2009...

Reviews: