Bleed Procedure
Fully extend the rebound damper shaft. Push the syringe handle down, then
release the plunger. Allow the bladder to come to a natural resting position
by waiting a few moments until the syringe stops filling.
Use a rag to cover the bleed tip and Charger bleed port, then unthread and
remove the syringe.
⚠
CAUTION - EYE HAZARD
Fluid may eject from the bladder assembly if the bladder is not in its resting
position. Wear safety glasses.
Install the bleed screw.
Cycle the rebound damper shaft a few times.
Remove the bottom bolt from rebound damper shaft.
Clean the Charger 2 Damper™ assembly.
13
14
T10
1.1-2.3 N·m (10-20 in-lb)
15