55
Remote Cable and Housing Installation - RTR Only
R e m o t e C a b l e a n d H o u s i n g I n s t a l l a t i o n - R T R O n l y
To install new cable and housing into the OneLoc™ remote, consult the OneLoc Remote User Manual on
www.sram.com/service
.
P a r t s , T o o l s , a n d S u p p l i e s
Parts
• AM SVC kit 200h/1yr SDLX RMT A1
• RMT Spring kit DLX/SDLX/SDLXC
• Shift cable and housing
Safety and Protection Supplies
• Safety glasses
• Nitrile gloves
Common Tools
• 2 and 3 mm hex wrenches
• 2 and 3 mm hex bit sockets
• 5 mm open end wrench
• Torque wrench
• Cable and Housing Cutters
After the housing has been routed and installed on the bicycle, thread
the threaded ferrule onto the housing.
Do not push the housing into the threaded ferrule.
Install the threaded ferrule and housing into the cable hanger, then
tighten the ferrule lock screw until it is flush with the cable hanger.
Thread the cable through the housing, spool, and under the cable
spool bolt. Pull the cable tight and tighten the cable set screw to
0.9 N
·
m (7 in-lb).
1
5 mm
2
2 mm
3
2 mm
0.9 N·m (8 in-lb)