33
Remote Spring Replacement - RTR Only
2 0 0 H o u r S e r v i c e
R e m o t e S p r i n g R e p l a c e m e n t - R T R O n l y
Loosen the cap screw from the reservoir and remove the remote
subassembly from the reservoir.
Clean the cam assembly.
Clamp grooved soft jaws into a vise. Gently clamp the cam into the
groove in the soft jaws.
Preload the spring clockwise until it stops, then remove the travel
limit screw. Carefully unload the spring and pull the cam from the cam
housing.
⚠
CAUTION
If not unloaded slowly, the spring can reset rapidly, causing the hex
wrench to eject from the cam assembly.
3 mm
1
2
1.5 mm
5 mm
5 mm
3
Grooved soft jaws