Charger Damper™ Assembly and Bleed
Fill the bleed syringe 1/3 full with 3wt suspension fluid and thread
the syringe into the compression top cap assembly.
Create a vacuum in the damper assembly by pulling up on the
syringe handle and simultaneously pushing up on the rebound
damper shaft. This will force bubbles out of the damper assembly.
Pressurize the damper assembly by pushing down on the syringe
handle and simultaneously pulling down on the rebound damper
shaft.
Continue to hold down on the syringe handle and simultaneously
cycle the rebound damper shaft a few times to purge bubbles.
The bladder will expand and contract. This is normal.
Repeat pulling a vacuum and pressurizing the damper assembly
until only very small bubbles emerge from the damper assembly.
21
3wt
22