27
Charger Damper Removal
Use your fingers or a pick to remove the o-ring from the low speed
compression needle.
Use your fingers to install a new o-ring.
Use a 24 mm socket to loosen and remove either the coupler or
the compression top cap from the bladder, whichever loosens first.
Remove the assembly from the vise.
24
25
24 mm