Technical Bulletins
The following pages include Spectra’s most commonly used technical bulletins, covering tests,
adjustments, troubleshooting, and common points of confusion. Many more technical bulle-
tins are available on the Spectra website, www.spectrawatermakers.com.
ACCUMULATOR PRESSURE
Your Spectra watermaker is supplied with a pressure accumulator tank (PL-ACC-TK), which
should be installed in the feed water line between the pre-filters and the Clark Pump.
The purpose of the feed line accumulator is to reduce the spikes in the feed pressure caused
by the cycling of the Clark Pump. If the accumulator is not properly charged it can lead to
problems with the Shurflo Pump pressure cutout switch (see page 58). The accumulator has a
Schrader air valve, like a car tire, which allows the internal air bladder of the accumulator to
be pre-charged. The accumulator should be pumped up to about 65 psi (4.5 bar) for best re-
sults. Add air using a tire pump or air compressor. You can experiment with the exact pressure
that will give the best pulsation dampening on your installation.
Schrader valve
Connections to feed
water hose, between
Shurflo pump and
Clark Pump
Analogue feed pressure
gauge
Summary of Contents for Ventura 150T MPC
Page 2: ...2 ...
Page 4: ...4 ...
Page 7: ...7 Installation ...
Page 8: ...8 ...
Page 14: ...14 ...
Page 28: ...28 ...
Page 29: ...29 Operation ...
Page 30: ...30 ...
Page 38: ...38 ...
Page 39: ...39 Maintenance Storage and Troubleshooting ...
Page 40: ...40 ...
Page 60: ...60 ...
Page 61: ...61 MPC 5000 Programming and Controls ...
Page 62: ...62 ...
Page 72: ...72 ...
Page 74: ...74 ...
Page 75: ...75 Exploded Views and Part Numbers ...
Page 76: ...76 ...
Page 84: ...84 Parts HP CYL 3 4R ...
Page 85: ...85 PL MTS 3 8X1 2S HP CYL SST HP CYL CCA SO HPP ECCB HP CYL EC HP CYL R HP CYL PT Parts ...
Page 86: ...86 ...