33
Product
The Ventura 150 produces 6-6.5 Gallons Per Hour (GPH) or 26—27 Liters Per Hour (LPH) of
product (fresh) water.
The Ventura 200T produces 7.7-8.5 GPH (29—32LPH)
MPC Display Modes
(Scroll through the modes with the Alarm Display key.)
Salinity
Salinity readout displays the conductivity of the product water in parts per million (PPM).
Anything below 750 PPM is considered potable, and will be diverted to the tanks.
Feed Pressure
Ventura 150 feed water pressure range is 60—70 PSI (4.2—5 BAR)
Ventura 200T feed water pressure range is 80—90 PSI (5.5—6.2 BAR)
Filter Condition
When filters become partially clogged, the empty blocks on the bar graph on the MPC-
5000 will gradually fill in. If the filters become fully clogged (all squares highlighted) the
unit will shut off automatically and alarm “Service Prefilters.”