Z-Ion Installation
The Z-Ion replaces the fresh water flush module on the feed pump module, and will come in-
stalled if you ordered your system with the optional Z-Ion. The Z-Ion filter bowl, like the nor-
mal fresh water flush module, houses the charcoal filter, which must be replaced every six
months.
The Z-Ion control box comes with four-foot cables for flexibility in mounting on the bulkhead
above or adjacent to the feed pump module.
Plug the connector from the Z-Ion generator bowl into the connector from the Z-Ion control
box.
Connect the power/signal cable, marked green, from the Z-Ion control box to the Z-Ion control
cable, also marked green, coming from the MPC box.
1.5 GPM Flow regulator
Manual shut-off valve (close
when changing filters)
Solenoid valve (opens during fresh
water flush/Z-Ion treatment)
Z-Ion control box
Connector to generator
bowl (2-pin)
Connector to MPC control box
(3-pin, labeled green)