68
Spectra MPC 5000 Operation Guide
This document outlines the MPC 5000 with Battery Backup operation. It details what is seen
on the display, what outputs are active during run-time, and the functions of the different
modes.
Catalina 340 Z systems use a single feed pump that runs at two speeds (run speed and service
speed), with an added boost pump to ensure adequate water supply to the feed pump. These
systems have two pressure sensors: The first is mounted before the feed pump to measure
boost pump pressure and filter condition. The second is mounted after the feed pump to
measure feed water pressure to the Clark Pump.
Catalina systems use
software Version A-40
USB Type B Computer
Connection
JP2 Jumper on (Catalina 340
Z and all Mk II systems)
JP1 Jumper on (all systems)
Battery
MPC 5000 Circuit Board
Salinity Probe
Plug
Display Jacks