38
Note: You can bypass the purge sequence and initiate a normal start at any time by Pressing
“Auto Run” and “Stop”
simultaneously. This will bypass the purge sequence and ena-
ble a normal start. If you must stop the purge sequence for any reason, the control
will default back to the beginning of the purging mode to protect your system. Be
sure to purge the system of chemicals for at least twenty minutes. DO NOT BYPASS
THE PURGE MODE UNLESS YOU ARE ABSOLUTELY SURE THAT THE CHEMICALS ARE
PURGED FROM THE SYSTEM, OR YOU WILL PERMANENTLY DAMAGE THE MEM-
BRANE.
1. After the purge sequence, the control will alarm with the message “Close Pressure Relief
Valve.” Remove the tag and washer, if you haven’t done so, close the pressure relief
valve, and proceed by pressing Auto Run.
2. The system should now be running under pressure and making water. The display will read
“PURGING PRODUCT WATER,” and count down another ten minutes while it purges any re-
sidual chemicals from the membrane and product lines. After ten minutes, if product water
is below 750 PPM it will send the product water to the tank. Carefully inspect for leaks over
the entire system. Shut down the system and repair any leaks you find.
3. The system is now operational, and you may run your system as you desire. It is best to use
the Auto Run button which defaults to the automatic fresh water flush after the unit is fin-
ished making water. If you shut down the system by pressing the Stop button the system
will not fresh water flush. If you do stop the system using the Stop button, use the Auto
Store button to effect a fresh water flush. You should fresh water flush your watermaker
after every use.
4. Check that the system is operating within its normal parameters. Compare with the parame-
ters on the next page.
Note: All new Spectra systems are fully tested in the factory, then stored for shipping with
propylene glycol, a food grade antifreeze and preservative. In some cases propylene glycol can
be difficult to flush from the membrane. If you experience high salinity or a residual taste in the
product water after commissioning a new system, please contact Spectra for additional tips on
flushing propylene glycol from the membrane.
The system will go into a starting mode and the feed pump will start shortly thereafter. The
fresh water flush solenoid will open, allowing water from your pressurized fresh water system
to help prime the pump. The system should prime within 30 seconds. Check the strainer and
the brine discharge for water flow. There should be few bubbles anywhere in the intake hoses
and the feed pump should sound smooth after priming. After confirming that the system is
primed, inspect for leaks.
Note: The reject light will be on whenever the
product water is being rejected or not being
made. When the product water is below 750
PPM the green (Good) light will show that water
is going to the tank.
New System Start-Up and Testing continued...
Summary of Contents for Catalina 340 Z
Page 2: ...2 ...
Page 4: ...4 ...
Page 6: ...6 ...
Page 8: ...8 ...
Page 10: ...10 ...
Page 11: ...11 Installation ...
Page 12: ...12 ...
Page 22: ...22 John Guest Super Speedfit Fittings ...
Page 34: ...34 ...
Page 35: ...35 Operation ...
Page 36: ...36 ...
Page 44: ...44 ...
Page 45: ...45 Maintenance Storage and Troubleshooting ...
Page 46: ...46 ...
Page 64: ...64 ...
Page 65: ...65 MPC 5000 Programming and Controls ...
Page 66: ...66 ...
Page 76: ...76 ...
Page 78: ...78 ...
Page 79: ...79 Exploded Views and Part Numbers ...
Page 80: ...80 ...
Page 88: ...88 Parts ...
Page 89: ...89 Parts PL MTS 3 8X1 2B HP CYL SST HP CYL CCA SO HPP ECCB HP CYL EC HP CYL R HP CYL PT Parts ...
Page 90: ...90 ...