41
Normal Operation and Fresh Water Flush
If the system has been pickled or stored, use the New System Startup procedure on page 39.
You should fresh water flush your watermaker after every use. Remember that you need to
run the system almost a half hour to make enough fresh water for one flush. You may notice
that the system output is higher when charging your batteries, as the watermaker is voltage
sensitive.
1. Check to see that the inlet and brine discharge seacocks are open.
2. Push Auto Run one or more times. The machine will run for one hour for each time the
button is pushed, then shut off and automatically do a fresh water flush/Z-Ion treatment.
3. Run the system until you have filled your tank or have made enough to meet your require-
ments for several days.
4. After the system fresh water flushes and shuts down it will enter the Auto Store mode,
which will flush the system at programmed intervals. See the next page.
5. You may stop the system at any time with the Stop button. If the Stop button is pressed
during operation, the system will not flush itself or go into Auto Store mode.
Auto Store mode: The timer counts down the hours until the next Fresh Water Flush.
Summary of Contents for Catalina 340 Z
Page 2: ...2 ...
Page 4: ...4 ...
Page 6: ...6 ...
Page 8: ...8 ...
Page 10: ...10 ...
Page 11: ...11 Installation ...
Page 12: ...12 ...
Page 22: ...22 John Guest Super Speedfit Fittings ...
Page 34: ...34 ...
Page 35: ...35 Operation ...
Page 36: ...36 ...
Page 44: ...44 ...
Page 45: ...45 Maintenance Storage and Troubleshooting ...
Page 46: ...46 ...
Page 64: ...64 ...
Page 65: ...65 MPC 5000 Programming and Controls ...
Page 66: ...66 ...
Page 76: ...76 ...
Page 78: ...78 ...
Page 79: ...79 Exploded Views and Part Numbers ...
Page 80: ...80 ...
Page 88: ...88 Parts ...
Page 89: ...89 Parts PL MTS 3 8X1 2B HP CYL SST HP CYL CCA SO HPP ECCB HP CYL EC HP CYL R HP CYL PT Parts ...
Page 90: ...90 ...