18
Use the supplied 3/4” (19mm) suc-
tion hose (clear with black spiral)
from the inlet thru-hull to the boost
pump/sea strainer module, and from
the boost pump/sea strainer module
to the feed pump.
From the Clark pump brine discharge con-
nector use the supplied 5/8 (16 mm) clear
braided vinyl hose with Quick Connect
fitting to the brine overboard fitting.
Plumbing Schematic
Flush water from ship’s
pressure water system
25 psi (2bar) minimum
Use part of the 25-feet (8 meters)
of 1/2-inch vinyl hose, pre-fitted
with a 1/2-inch John Guest stem
fitting, to connect the feed pump
to the Clark Pump feed water inlet.
(see following pages)
Use the 1/2-inch vinyl hose with
the Quick Connect fitting be-
tween the Z-Ion/fresh water
flush module and the top of the
sea strainer. (see following pag-
es)
The optional Z-ION will re-
place the Fresh Water
Flush module
Summary of Contents for Catalina 340 Z
Page 2: ...2 ...
Page 4: ...4 ...
Page 6: ...6 ...
Page 8: ...8 ...
Page 10: ...10 ...
Page 11: ...11 Installation ...
Page 12: ...12 ...
Page 22: ...22 John Guest Super Speedfit Fittings ...
Page 34: ...34 ...
Page 35: ...35 Operation ...
Page 36: ...36 ...
Page 44: ...44 ...
Page 45: ...45 Maintenance Storage and Troubleshooting ...
Page 46: ...46 ...
Page 64: ...64 ...
Page 65: ...65 MPC 5000 Programming and Controls ...
Page 66: ...66 ...
Page 76: ...76 ...
Page 78: ...78 ...
Page 79: ...79 Exploded Views and Part Numbers ...
Page 80: ...80 ...
Page 88: ...88 Parts ...
Page 89: ...89 Parts PL MTS 3 8X1 2B HP CYL SST HP CYL CCA SO HPP ECCB HP CYL EC HP CYL R HP CYL PT Parts ...
Page 90: ...90 ...