Fail Safe Operation
During the actual running of any program (PZ or a user created
program), if the release button (
12
) is pressed once, this action will:-
A) Abort a program if the load is actually rising or releasing.
B) Step on to the next segment of a program if a Hold Time function
(up to 99.9 minutes) or Infinite Hold is operating.
To stop a program at any stage the release button (
12
) is pressed
twice in quick succession. In this way use of the release button acts to
release any stored load on the press and allows safe access to any
work within the pressing area (
6
) when the safety guard (
5
) is raised.
A status message “Stop Key Pressed” will be shown.
2) Directory Screen
The Directory Screen is accessed from the Operation Screen by
selecting DIR using the left (
14
) or right (
15
) button to illuminate and
accepting by pressing the accept (tick) button (
16
).
The Directory Screen allows for checking of any programs and their
segment details that have been stored on the Atlas Auto press for its
operation. Up to 6 user created programs (P1 to P6) can be stored.
The simple operation program PZ is always stored and cannot be
changed.
When the Directory Screen is selected from the Operation Screen, the
first type of screen that may be typically presented is shown as DIR1.
DIR1
Summary of Contents for Atlas Automatic 40 Ton
Page 1: ...Atlas Automatic 40 Ton 40T Hydraulic Press User Manual 2I 25470 4...
Page 2: ......
Page 3: ...Atlas Automatic 40 Ton 40T Hydraulic Press User Manual 2I 25470 4...
Page 17: ...Atlas Auto 40T Hydraulic Press 15 Back View Front Safety Guard Raised 9 17 3 5 19...
Page 18: ...User Manual 16 Detail Of Electronic Front Control Panel 4 11 12 13 14 15 16 1 2...
Page 32: ...User Manual 30...
Page 65: ...Atlas Auto 40T Hydraulic Press 63 13 EC Declaration of Conformity...