B-8
SPARC Enterprise M3000 Server Installation Guide • March 2012
■
Degraded: The component is operating. However, either an error has been
detected or the component is faulty. As a result, the component might be
operating with reduced functionality or performance.
■
Deconfigured: As a result of another component's faulted or degraded status, the
component is not operating. (The component itself is not faulted or degraded.)
■
Maintenance: The component is under maintenance. A
deletefru
(8),
replacefru
(8), or
addfru
(8) operation is currently underway.
Example of
showstatus
output
B.3.4
Using the
fmdump
Command
The
fmdump
command displays the contents of any log files managed by the
module called Fault Manager.
This example assumes there is only one fault.
B.3.4.1
fmdump -V
Command
You can obtain information in more detail with the
-V
option, as shown in the
following example.
At least three lines of new output are delivered by the
-V
option:
■
The first line is a summary of the information that you have seen before in the
console message, including the timestamp, UUID, and message ID.
XSCF>
showstatus
FANBP_B Status:Normal;
* FAN_A#0 Status:Faulted;
XSCF>
#
fmdump
TIME UUID SUNW-MSG-ID
Nov 02 10:04:15.4911 0ee65618-2218-4997-c0dc-b5c410ed8ec2 SUN4-8000-0Y
#
fmdump -V -u 0ee65618-2218-4997-c0dc-b5c410ed8ec2
TIME UUID SUNW-MSG-ID
Nov 02 10:04:15.4911 0ee65618-2218-4997-c0dc-b5c410ed8ec2 SUN4-8000-0Y
100% fault.io.fire.asic
FRU: hc://product-id=SUNW,A70/motherboard=0
rsrc: hc:///motherboard=0/hostbridge=0/pciexrc=0
Summary of Contents for Enterprise M3000
Page 4: ......
Page 8: ...viii SPARC Enterprise M3000 Server Installation Guide March 2012 ...
Page 34: ...3 14 SPARC Enterprise M3000 Server Installation Guide March 2012 ...
Page 42: ...4 8 SPARC Enterprise M3000 Server Installation Guide March 2012 ...
Page 60: ...B 10 SPARC Enterprise M3000 Server Installation Guide March 2012 ...