3-12
SPARC Enterprise M3000 Server Installation Guide • March 2012
4. From the XSCF Shell, type the
showhardconf
command with the
-u
option.
5. Check the number of FRUs mounted on the server against the product test record.
For an output example of
showhardconf -u
, refer to
Section B.3.1.1,
“showhardconf -u Command” on page B-6
.
6. From the XSCF Shell, type the
console
command with the
-d 0
option.
This switches you from the XSCF console back to the domain console (OS console)
and displays the ok prompt.
7. At the
ok
prompt, type the
probe-scsi-all
command.
8. Confirm that the CD-RW/DVD-RW drive unit and hard disk drive installed in the
server are recognized.
9. At the ok prompt, type the
show-devs
command.
10. Confirm that each installed PCIe card is recognized.
11. Compare the configuration shown by
showhardconf -u
,
probe-scsi-all
, and
show-devs
with the product test record.
If the configuration is incorrect, contact your sales representative.
12. Press the Enter, "#" (default escape character), and "." (period) keys.
This key combination switches you from the domain console (OS console) back to
the XSCF console.
3.5.2
Checking the Dual-Power Feed
For a system using the dual-power feed option, follow the procedure below to
confirm that the system can operate even if one power feed is stopped.
1. Confirm that the system is powered on by checking the output of the
showdomainstatus
-a
command from the XSCF Shell.
2. Switch off the AC power supply system on the PSU#0 side.
3. Confirm that the POWER LED on the operator panel is lit.
4. From the XSCF Shell, confirm a power failure by executing the
showlogs event
command.
XSCF>
console -d 0
Connect to DomainID 0?[y|n] :
y
ok
Summary of Contents for Enterprise M3000
Page 4: ......
Page 8: ...viii SPARC Enterprise M3000 Server Installation Guide March 2012 ...
Page 34: ...3 14 SPARC Enterprise M3000 Server Installation Guide March 2012 ...
Page 42: ...4 8 SPARC Enterprise M3000 Server Installation Guide March 2012 ...
Page 60: ...B 10 SPARC Enterprise M3000 Server Installation Guide March 2012 ...