5. Switch on the AC power supply system on the PSU#0 side (which was switched
off in Step 2).
6. From the XSCF Shell, confirm a power recovery by executing the
showlogs
event
command.
7. Confirm that the AC LED and DC LED on PSU#0 are lit.
8. From the XSCF Shell, confirm a Power Status is On by executing the
showhardconf
command.
9. Switch off the AC power supply system on the PSU#1 side.
10. Confirm that the POWER LED on the operator panel is lit.
11. From the XSCF Shell, confirm a power failure by executing the
showlogs event
command.
12. Switch on the AC power supply system on the PSU#1 side (which was switched
off in Step 9).
13. From the XSCF Shell, confirm a power recovery by executing the
showlogs
event
command.
3.6
Connecting Additional Peripheral
Devices
For details on how to add optional devices, such as additional memory or an
additional PCIe card, refer to the
SPARC Enterprise M3000 Server Service Manual
.
To add an additional storage device or other peripheral device, refer to the manual
supplied with the device.