3-10
SPARC Enterprise M3000 Server Installation Guide • March 2012
■
Domain to Service Processor Communications Protocol (DSCP) configuration
(setdscp) (Note 2)
■
Altitude setting (setaltitude) (Note 2)
■
Dual power feed option setting (setdualpowerfeed) (Note 3)
Note –
(1) To apply the settings, the XSCF unit must be reset with the
applynetwork
and
rebootxscf
commands.
Note –
(2) To apply the settings, the XSCF unit must be reset with the
rebootxscf
command.
Note –
(3) To apply changes made with the
setdualpowerfeed
command, power
to the server must be completely disconnected and then reconnected (all power
cords must be disconnected and then reconnected). Wait at least 30 seconds before
reconnecting the power cords to the server.
2. Log in to the XSCF Shell with the user account and password that were set in Step
1.
For details on how to log in to a user account, refer to the
SPARC Enterprise
M3000/M4000/M5000/M8000/M9000 Servers XSCF User’s Guide
.
3.5
Powering On the Server
This section explains how to power on the server for the first time.
1. Set the key on the operator panel to the Service position.
2. From the XSCF Shell, type:
3. Confirm that the XSCF STANDBY LED (green) on the operator panel is lit.
4. Press the Power button on the operator panel to power on the server.
The server starts and begins a self-diagnosis.
Watch the administration console for error messages during this boot process. For
details on troubleshooting during installation, refer to
Appendix B
.
XSCF>
console -d 0
Connect to DomainID 0?[y|n] :
y
Summary of Contents for Enterprise M3000
Page 4: ......
Page 8: ...viii SPARC Enterprise M3000 Server Installation Guide March 2012 ...
Page 34: ...3 14 SPARC Enterprise M3000 Server Installation Guide March 2012 ...
Page 42: ...4 8 SPARC Enterprise M3000 Server Installation Guide March 2012 ...
Page 60: ...B 10 SPARC Enterprise M3000 Server Installation Guide March 2012 ...