5-6
VPH-G90E/G90U/G90M
6. Adjust RV302 so that C section of a waveform is 0
±
0.01 V dc.
Specification: C level = 0
±
0.01 V dc
5-4-6. H SIN
x
x
x
x
x
VP Waveform Adjustment
(DB Board)
1. Input the signal of its frequency is 64 kHz.
2. Set the data value of H SIZE COARSE to “250.”
3. Set the data value of V SIZE COARSE to “180.”
4. Connect an oscilloscope to TP102.
5. Adjust RV202 so that A section of an envelope
waveform is 0 V.
5-4-4. H Parabola Waveform Adjustment
(DA Board)
1. Input the signal of its frequency is 64 kHz.
2. Set the data value of H SIZE COARSE to “240.”
3. Set the data value of V SIZE COARSE to “maximum.”
4. Connect an oscilloscope to TP402.
5. Adjust RV301 so that A section of a waveform is
identical with B section.
Specification: A level = B level
A
B
C
0 V
±
0.01 V dc
5-4-5. H SIN Adjustment (DA Board)
1. Input the signal of its frequency is 64 kHz.
2. Set the data value of H SIZE COARSE to “240.”
3. Set the data value of V SIZE COARSE to “maximum.”
4. Connect an oscilloscope to TP403.
5. Adjust RV402 so that A section of a waveform is
identical with B section.
Specification: A level = B level
6. Adjust RV403 so that voltage of A and B sections are 0
±
0.01 V dc.
Specification: A and B voltages = 0
±
0.01 V dc
7. Repeat steps 5 and 6 until satisfy the specifications.
7. Repeat steps 5 and 6 until satisfy the specifications.
A
A
B
B
0 V
±
0.01 V dc
0 V dc
A
Summary of Contents for VPH-G90E
Page 10: ......
Page 120: ......
Page 122: ...2 2 VPH G90E G90U G90M 2 1 3 Location 3 ME MB MC PB M L MA BA F BC NA BB ...
Page 190: ......
Page 204: ......
Page 210: ......
Page 224: ......
Page 337: ...9 1 9 1 VPH G90E G90U G90M SECTION 9 BLOCK DIAGRAMS ...
Page 363: ...2 3 4 5 A B C D E F G H 1 10 1 10 1 VPH G90J G90E G90U G90M SECTION 10 DIAGRAMS ...
Page 437: ...2 3 4 5 A B C D E F G H 1 10 75 10 75 VPH G90J G90E G90U G90M ...
Page 474: ...2 3 4 5 A B C D E F G H 1 10 112 10 112 VPH G90J G90E G90U G90M ...