1-78
VPH-G90E/G90U/G90M
94
Adjustments
Adjustments
Adjusting the Registration
Notes
• The center of the screen and the center of the CROSS HAIR pattern can
be aligned by performing the centering adjustment.
For details, see “Green CENT (centering) adjustment” on page 95.
• When the optical axis angle is smaller, the HATCH pattern becomes
trapezoidal. Perform the KEY (keystone) adjustment to correct the
distortion.
For details, see “Green KEY and PIN adjustments for the whole screen” on
page 100.
Keys for Adjusting
Indications on the REGISTRATION keys and the adjustment
items
REGISTRATION
(CENT/SIZE/LIN/SKEW/BOW/KEY/
PIN/ZONE) keys
PATTERN key
NORMAL key
BLKG key
RESET key
Arrow (
B
/
b
/
V
/
v
) keys
PO/– keys
CUT OFF R/G/B keys
ADJ R/G/B keys
PO/– keys
Indicated on the commander
Adjustment Items
CENT
Centering
SIZE
Size
LIN
Linearity
SKEW
Skew
BOW
Bow
KEY
Keystone
PIN
Pincushion
ZONE
Zone
SELECT
VIDEO MEMORY
SWITCHER INDEX
PIC
ON
AUDIO
OFF
PATTERN
FOCUS
ZOOM
SHIFT
NORMAL
MUTING
STATUS
LCD LENS CONTROL
ON
COMMAND
OFF
SIZE
DOT PHASE
APA
SHIFT
RGB
R
B
CENT
ON
STANDBY
MEMORY
MENU
VIDEO
INPUT SELECT
A
D
B
C
BLKG
SYS SET
RESET
FUNCTION
1
4
2
3
5
8
6
7
9
10/0(ALL)
SW NO/
OFF/GROUP
SWITCHER/VIDEO MEMORY/INDEX
ENTER
POSITION
BRIGHT
CONTR
PICTURE CONTROL
HUE
COLOR
SHARP
VOL
VIDEO/S VIDEO
LIGHT
R
G
CENT
SIZE
CUT OFF
B
LIN
R
G
ADJ
B
BIAS
GAIN
W/B
MG FOCUS
LENS
FOCUS
SKEW
BOW
REGISTRATION
KEY
PIN
ZONE
POSITION
Adjustments
95
Adjustments
Adjusting the Green Registration
Be sure to adjust the green registration first.
1
Green CENT (centering) adjustment
Adjust so that the center of the test pattern is aligned with the center of the
screen.
1
Press the CENT key.
The CROSS HAIR pattern and the cursor appear.
2
Press the ADJ G key.
3
Press the CUT OFF R and B keys to display green only.
4
Reset the FINE centering data.
See “Resetting the Data” on page 138.
5
Press the arrow keys to align the center of the CROSS HAIR pattern
with the center of the screen.
C E N T A D J
- G - C O A R S E
H c : [ 1 2 8 ]
H f : 1 2 8
V c : 1 2 8
V f : 1 2 8
ADJ:
6
If the test pattern is not aligned with the center, press the CENT key
again.
The projector enters the FINE centering mode for fine adjustment.
Each time you press the CENT key, the COARSE mode and FINE
mode are selected alternately, and you can use the two modes
appropriately. The adjustment data is stored for each mode separately.
While you hold down the arrow key in the FINE mode, “f” is displayed
around the adjustment position.
7
Press the arrow keys to align the center precisely.
Notes
• If the test pattern is off-centered by a large amount, check if the projector
is installed or adjusted correctly.
• If the upper, lower, left or right part of the screen is de-focused, check if
the scheimpflug is adjusted correctly.
For details, see “Adjusting the green scheimpflug” on page 83.
Summary of Contents for VPH-G90E
Page 10: ......
Page 120: ......
Page 122: ...2 2 VPH G90E G90U G90M 2 1 3 Location 3 ME MB MC PB M L MA BA F BC NA BB ...
Page 190: ......
Page 204: ......
Page 210: ......
Page 224: ......
Page 337: ...9 1 9 1 VPH G90E G90U G90M SECTION 9 BLOCK DIAGRAMS ...
Page 363: ...2 3 4 5 A B C D E F G H 1 10 1 10 1 VPH G90J G90E G90U G90M SECTION 10 DIAGRAMS ...
Page 437: ...2 3 4 5 A B C D E F G H 1 10 75 10 75 VPH G90J G90E G90U G90M ...
Page 474: ...2 3 4 5 A B C D E F G H 1 10 112 10 112 VPH G90J G90E G90U G90M ...