SRP-X500P RS-232C Interface Manual
Parameters
The parameter consists of 108 bytes of data, as shown in the following table.
Byte (when
acquiring all
items at one time)
Parameter Specified
value
(when acquiring
single item)
Parameter byte(s)
(when acquiring
single item)
1st
PROJECTOR PROTOCOL SWITCH
0x51 (‘Q’)
1
2nd
SYSTEM TYPE SWITCH
0x52 (‘R’)
1
3rd-8th INPUT
VOLUME
0x53
(‘S’)
6
9th
MASTER VOLUME LEVEL
0x54 (‘T’)
1
10th
REMOTE 1 LEVEL
0x55 (‘U’)
1
11th
REMOTE 2 LEVEL
0x56 (‘V’)
1
12th
REMOTE 3 LEVEL
0x57 (‘W’)
1
13th
REMOTE 4 LEVEL
0x58 (‘X’)
1
14th
REMOTE 5 LEVEL
0x59 (‘Y’)
1
15th
REMOTE 6 LEVEL
0x5A (‘Z’)
1
16th-21st
INPUT LEVEL
0x5B (‘[‘]
6
22nd-29th
OUTPUT LEVEL
0x5C (‘\’)
8
30th
INPUT MUTING
0x5D (‘]’)
1
31st, 32nd
OUTPUT MUTING
0x5E (‘^’)
2
33rd
MASTER MUTING
0x5F (‘_’)
1
34th
REMOTE MUTING
0x60 (‘`’)
1
35th (RESERVED)
36th
RF/AF INDICATOR
0x61 (‘a’)
1
37th
WL INDICATOR
0x62 (‘b’)
1
38th
+48V SWITCH
0x63 (‘c’)
1
39th
MIC 1 TRIM
0x64 (‘d’)
1
40th
MIC 2 TRIM
0x65 (‘e’)
1
41st
MIC 3 TRIM
0x66 (‘f’)
1
42nd
MIC 4 TRIM
0x67 (‘g’)
1
43rd LINE
TRIM
0x68
(‘h’)
1
44th-48th AV/RGB
TRIM
0x69
(‘i’) 5
49th
REF INDICATOR
0x6A (‘j’)
1
50th-53rd FR
0x6B
(‘k’) 4
54th,55th
FR SETUP STATUS
0x6C (‘l’)
2
56th
AV/RGB INPUT SELECT
0x6D (‘m’)
1
57th, 58th
SPEAKER OUTPUT LEVEL
0x6E (‘n’)
2
59th
IR OUTPUT MODE INDICATOR
0x6F (‘o’)
1
60th-75th
LEVEL METER
0x70 (‘p’)
16
76th PROTECTION
0x71
(‘q’)
1
77th
CLIP INDICATOR
0x72 (‘r’)
1
78th, 79th
TEMPERATURE
0x73 (‘s’)
2
80th PROJECTOR
ON/STANDBY
INDICATOR
0x74 (‘t’)
1
81st, 82nd
(RESERVED)
83rd
EMG MUTING
0x77 (‘w’)
1
84th
SCENE No.
0x78 (‘x’)
1
85th-94th
PARALLEL INPUT
0x79 (‘y’)
10
95th, 96th
PARALLEL OUTPUT
0x7A (‘z’)
2
97th
FAN MOTOR
0x7B (‘{‘}
1
98th
MASTER VOLUME CONTROL
0x7C (‘|’)
1
99th-108th
GAIN REDUCTION
0x7D (‘}’)
10
The parameters returned have the following meanings.
Page 25/43