SRP-X500P RS-232C Interface Manual
♦
FR (50th-53rd byte)
The FR parameter consists of the 4 bytes of data in the order shown in the following table.
Byte Parameter
1st
MIC 1/WL 1 FR
2nd
MIC 2/WL 2 FR
3rd
MIC 3 FR
4th
MIC 4 FR
•
FR
Shows the status of the FEED BACK REDUCER. The correspondence of the parameter with
the FEED BACK REDUCER setting is shown in the following table.
FR
Turned off
0x30 (‘0’)
Turned on
0x31 (‘1’)
Setting up in progress
0x32 (‘2’)
Cancellation in progress
0x33 (‘3’)
♦
FR SETUP STATUS (54th and 55th byte)
The FEED BACK REDUCER setup status parameter consists of the 2 bytes of data in the order shown
in the following table.
Byte Parameter
1st SETUP
CHANNEL
2nd SETUP
STATUS
•
SETUP CHANNEL
Shows the channel for which the FEED BACK REDUCER setting is in progress.
The parameter and the channel are shown in the following table.
Channel
Normal operation
0x30 (‘0’)
MIC 1/WL 1
0x31 (‘1’)
MIC 2/WL 2
0x32 (‘2’)
MIC 3
0x33 (‘3’)
MIC 4
0x34 (‘4’)
CANCEL 0x35
(‘5’)