SRP-X500P RS-232C Interface Manual
Return packet format
When the SRP-X500P receives the command successfully, the parameter is returned together with an ACK
(0x41 (‘A’)) in the order shown below.
0x41
“
parameter” 0x0D
The parameter consists of 8 bytes of data and is the same as that of the OUTPUT FADER command.
2.1.7 REMOTE 1-6 LEVEL : 0x43 0x4C 0x56 0x4C (‘CLVL’)
This command is used to set the level of the REMOTE faders.
The level of the REMOTE faders are reset to 0 dB when the SRP-X500P is turned off.
Packet format
0x43 0x4C 0x56 0x4C
“
parameter” 0x0D
♦
Parameter
The parameter consists of 2 bytes of data in the order shown in the following table.
Byte Parameter
1st Channel
2nd LEVEL
•
Channel (1st byte)
Specifies the REMOTE fader channel.
The parameter and the REMOTE fader channel are as shown in the following table.
Channel
REMOTE 1
0x42 (‘B’)
REMOTE 2
0x43 (‘C’)
REMOTE 3
0x44 (‘D’)
REMOTE 4
0x45 (‘E’)
REMOTE 5
0x46 (‘F’)
REMOTE 6
0x47 (‘G’)
Page 10/43