SRP-X500P RS-232C Interface Manual
•
LEVEL (2nd byte)
The level for each fader can be specified (in dB units).
The parameter and the level are as shown in the following table.
Level
Level
Level
-
∞
0x30 (‘0’)
-20.0
0x40 (‘@’)
-4.5
0x50 (‘P’)
-70.0
0x31 (‘1’)
-19.0
0x41 (‘A’)
-4.0
0x51 (‘Q’)
-60.0
0x32 (‘2’)
-18.0
0x42 (‘B’)
-3.5
0x52 (‘R’)
-55.0
0x33 (‘3’)
-17.0
0x43 (‘C’)
-3.0
0x53 (‘S’)
-50.0
0x34 (‘4’)
-16.0
0x44 (‘D’)
-2.5
0x54 (‘T’)
-45.0
0x35 (‘5’)
-15.0
0x45 (‘E’)
-2.0
0x55 (‘U’)
-40.0
0x36 (‘6’)
-14.0
0x46 (‘F’)
-1.5
0x56 (‘V’)
-35.0
0x37 (‘7’)
-13.0
0x47 (‘G’)
-1.0
0x57 (‘W’)
-32.5
0x38 (‘8’)
-12.0
0x48 (‘H’)
-0.5
0x58 (‘X’)
-30.0
0x39 (‘9’)
-11.0
0x49 (‘I’)
0
0x59 (‘Y’)
-27.5
0x3A (‘:’)
-10.0
0x4A (‘J’)
-25.0
0x3B (‘;’)
-9.0
0x4B (‘K’)
-24.0
0x3C (‘<‘)
-8.0
0x4C (‘L’)
-23.0
0x3D (‘=‘)
-7.0
0x4D (‘M’)
-22.0
0x3E (‘>‘)
-6.0
0x4E (‘N’)
-21.0
0x3F (‘?’)
-5.0
0x4F (‘O’)
Example
To set the REMOTE fader 1 to 0 dB
0x43 0x4C 0x56 0x4C 0x42 0x59 0x0D
(‘C L V L B Y CR’)
2.1.8 REMOTE FADER LEVEL PARAMETER REQUEST : 0x52 0x4C 0x56
0x4C (‘RLVL’)
This command is used to read the master volume and REMOTE fader level settings from the SRP-X500P.
Packet format
0x52 0x4C 0x56 0x4C 0x0D
Return packet format
When the SRP-X500P receives the command successfully, the parameter is returned together with an ACK
(0x41 (‘A’)) in the order shown below.
0x41
“
parameter” 0x0D