RPN Correction Procedure
The RPN correction procedure is shown below.
RPN exists.
Press the AUTO W/B BAL switch
to the BLACK side for 10 seconds.
Perform RPN Adjustment.
Refer to “RPN Menu”
RPN is removed?
No
No
RPN is corrected?
RPN is corrected?
Yes
No
Correction
OK
Yes
Correction is not possible.
Replace the CCD block.
Yes
Correction
OK
Possibility NG under the adjacent
conditions.
Delete registrations of peripheral small
RPNs and execute re-registration.
Correction
OK
Knee Adjustment
Weaken Blue Knee Station effective, Blue Fringe is made inconspicuous.
Blue Fringe is the most made inconspicuous at "-4".
VCO Adjustment
The VCO Adjustment menu allows adjustment of VCO frequency.
Clock Out Select
Set the Clock Out Select to ON, master clock signal can be output to VIDEO OUT connector.
Clock Frequency
The Clock Frequency setting allows adjustment of the 27 MHz master clock frequency.
Adjusting VCO
Preparation
Connect a frequency counter to the VIDEO OUT connector.
PXW-X500