Time codes recorded for Mark IN/OUT points
There is a gap between actual time codes and Mark IN/
OUT time codes recorded in the cassette memory, as
shown in the figure below. The frame digit is
incremented at each Mark IN point and is decremented
at each Mark OUT point.
12:23:15:10
12:34:20:20
12:39:24:23
12:23:16
12:34:20:20
12:39:24
Actual time code
(The Index
Picture is the
image around
12:23:15:10.)
Mark IN
(or Rec IN)
Mark OUT
(or Rec OUT)
Rounded up
Rounded down
Time code
recorded in the
cassette memory
Recording capacity for Mark IN/OUT time
codes and Cue point time codes
When in MARK mode, up to 198 pairs of Mark IN and
Mark OUT points can be recorded (if using a cassette
with 16 Kbits of cassette memory).
When in CUE mode, up to 396 time codes points
(including all cue point time codes and all Mark (Rec)
IN and Mark (Rec) OUT time codes) can be recorded
(if using a cassette with 16 Kbits of cassette memory).
Cue