Chapter 8
Connections and Settings
122
Chapter 8
Connections and Settings
Connections for Cut Editing Using SDI Interface
(Optional DSBK-160A Required)
For a cut editing system using this unit together with a
DNW-A25/A25P Betacam SX VCR using an SDI
connection, the following figure shows an example of
the connections. In this example, the DNW-A25/A25P
is used as the recorder and this unit is used as the
player.
Settings on the DNW-A25/A25P
DNW-A25/A25P (recorder)
REF. VIDEO IN
REF. VIDEO OUT
SDI IN
SDI OUT
REMOTE
REMOTE
Note
In this case, the DSBK-160A SDI/i.LINK/DV Iuput/
Output Board is required.
1
75
Ω
coaxial cable (not supplied)
2
RCC-5G/10G/30G 9-pin remote control
cable (length 5 m (16 ft)/10 m (33 ft)/30
m (98 ft), not supplied)
DSR-70A/70AP (player)
1
2
1
Setting
TC INT/EXT switch
INT
Sub LCD menu
PRESET/REGEN item
(General settings page (1))
PRESET
Sub LCD menu
F-RUN/R-RUN item
(General settings page (1))
F-RUN
(These cables are included in the optional BKNW-225 Docking Kit.)
Switch
Setting
REMOTE/LOCAL switch
LOCAL
Settings on the DSR-70A/70AP
Settings Required When Connecting an External
Editing Control Unit
When connecting an external editing control unit to
this unit and using this unit as a recorder, make the
following timecode settings on this unit and VCR
constant and DIP switch settings on the editing control
unit.
Timecode Settings on This Unit
Make the following timecode settings for this unit.
Switch
Setting
REMOTE/LOCAL switch
REMOTE
REF. VIDEO IN 75
Ω
termination switch
ON
Switch/menu