Chapter 7
Setup Menu
116
Chapter 7
Setup Menu
Extended Menu
Menu items in the 800s, relating to audio control (continued)
Menu items in the 900s, relating to digital process
Item number
Item name
Settings
912
SEQUENTIAL
RECORD INPUT
SIGNAL
Selects the signal input method for sequential recording on the recorder and player.
PAR:
The video and audio signals you will record are input to the recorder and player
separately.
CAS:
The video and audio signals you will record are input to the player, and input to
the recorder as output signals from the player.
Item number
Item name
Settings
808
INTERNAL AUDIO
SIGNAL
GENERATOR
Select the operation of the internal audio test signal generator.
SILNC:
Silent signal.
1kHz :
1-kHz, –20 dB FS sine wave signal.
When you select SG as the audio input in the input selection section of the upper control
panel, the audio test signal generated by the internal audio test signal generator is input.
811
AUDIO
REFERENCE
LEVEL
Select the audio reference level (headroom) for recording on tape.
–12dB
–16dB
–18dB
–20dB
The factory default setting is –20 dB (DSR-70A)/–18 dB (DSR-70AP).
812
AUDIO OUTPUT
LEVEL
Select the audio output reference level.
+4dB
0dB
–6dB
813
PEAK HOLD TIME
Set the peak hold time for the audio level meter in the range of
OFF (no peak hold) to
1.5 seconds in 0.1 second steps.
814
OVER RANGE
DISPLAY HOLD
Select whether to hold the audio level meter OVER display.
OFF:
Do not hold.
ON:
Hold.
821
AUDIO
ATTENUATE
WHEN DV TAPE
PLAYBACK
When playing back a tape recorded in consumer DV format, select whether to attenuate
the audio output level.
OFF:
Attenuate.
ON:
Do not attenuate.