2-42
DSR-300/P(E)/V1
Setting the Battery Before End
1. Set the SYSTEM MENU (refer to section 2-25-2), and
select the “Battery before end setting mode (Menu No.
501).” (Refer to Fig. E.)
2. Press the RESET (MENU SET) button to blink the
voltage on the display window (Fig. F).
3. Press the SHIFT button while pressing the ADVANCE
button.
4. Note down the voltage on the display window.
5. Change the value by pressing the ADVANCE button,
and move to the next digit with the SHIFT button (Fig.
G).
For your reference, the voltage increases by about 0.02 V
when the right digit value is increased by one step.
6. Press the RESET (MENU SET) button to write the set
value in the EEPROM. “YES” will be displayed when
the desired voltage is set (Fig. H). “no” will be
displayed when an error occurs while writing in the
EEPROM and the value could not be set (Fig. I). In this
case, repeat steps 1 to 6.
Note:
.....
The voltage value shown on the display
window is for reference only.
.....
If the value in step 4 was not taken down,
change the value using the values at
shipment on the previous page as reference.
.....
If this menu is set by mistake, always press
the MENU button to exit this menu. Never
press the RESET (MENU SET) button.
When pressing the RESET button, the data
being set will be written.
Display window (LCD)
I
Blinking menu No. (When changed)
The voltage display blinking
Save NG
H
Save OK
F
E
A/D conversion value blinking display
G