2-76
DSR-300/P(E)/V1
.....
Page 18 Various Setting 3
.....
Page 19 KNEE Setting 3
.....
Page 20 DETAIL Related Setting
Standard Setting
WHT CLIP
Standard value setting of white clip level:
255
White clip level lowers by decreasing the
standard setting value.
M.KNEE P
Standard value setting of master knee point:
300
M.KNEE S
Standard value setting of master knee slope:
90
Standard Setting
CRISP
Standard value setting of crisp level:
8
LEVEL DEP Standard value setting of level depend level:
52
APERTURE Standard value setting of aperture level:
128
Standard Setting
M.GAMMA
Standard value setting of master gamma:
132
R.GAMMA
R channel’s gamma offset setting:
±
0
B.GAMMA
B channel’s gamma offset setting:
±
0
GAMMA TBL
Selection of gamma table A/B:
B
M.BLACK
Standard value setting of master black:
*
2083
*
For DSR-300: 2083
For DSR-300P: 2075
M.GAMMA
R.GAMMA
B.GAMMA
GAMMA TBL
M.BLACK
:
:
:
:
:
132
±
0
±
0
2083
PAGE 18 (NEXT PREV )
EXIT MENU (YES PUSH)
WHT CLIP
M.KNEE P
M.KNEE S
255
300
90
:
:
:
PAGE 19 (NEXT PREV )
EXIT MENU (YES PUSH)
CRISP
LEVEL DEP
APERTURE
8
52
128
:
:
:
PAGE 20 (NEXT PREV )
EXIT MENU (YES PUSH)
.....
Page 21 IRIS Related Setting
Standard Setting
IRIS GAIN
Setting of auto iris gain:
128
Following speed of auto iris can be changed.
IRIS MODE
Setting of auto iris peak average ratio:
100
Set the ratio of auto iris’s peak and
average values.
IRIS SET
Setting of the target value of auto iris:
144
LOW LIGHT
Setting of low light warning indication level:
*
152
*
For DSR-300: 152
For DSR-300P: 160
IRIS GAIN
IRIS MODE
IRIS SET
LOW LIGHT
128
100
144
152
:
:
:
:
PAGE 21 (NEXT PREV )
EXIT MENU (YES PUSH)