MOUNTING ON WALLS, SETUP ORDER
1.
Before switching on for the first time, carefully remove the packaging material taking care not to damage
the appliance and power cable. Do not use the product if it is damaged in any way!
2.
The appliance can
be used together or without the towel dryer console. Slide the dryer console from the bottom to the space
provided for this purpose. In case of correct fixing, you will hear a click, and the console
will
stand stable on
its place.
Max. power is limited to 1000 W with console, it is 2000 W without console.
3.
For proper
operation, the free circulation of warm air must be ensured, so select the place of the wall- mounting
according to Figure 2.! It is forbidden to locate the unit directly under a wall outlet!
4.
Make holes for the
studs in the wall according to Figure 2.!
5.
Fasten the wall console (8) to the wall, facing the groove upside,
to be able to hang on the appliance.
6.
Hang the appliance on the wall-console, and drive in the upper
safety screw.
7.
Drive the third screw as well into the lower stud.
8.
Make sure, the appliance is fixed stable
on wall!
9.
Plug the unit into a standard grounded wall socket.
10.
Now the unit is ready for operation.
Caution: Risk of electric shock!
Do not attempt to disassemble or modify the unit or its
accessories. In case any part is damaged, immediately power off the unit and seek the assistance
of a specialist
.
In the event that the power cable should become damaged, it should only be replaced by the
manufacturer, its service facility or similarly qualified personnel.
Meaning of symbol on appliance:
Do not cover!
Covering the unit can cause overheating, fire or electric shock!
FEATURES
wall mounted heater with fan for warming the air of indoor spaces, and drying clothes washed in water
•
IPX1 protection against vertically dripping water
•
adjustable power (1000 W / 2000 W)
•
with towel dryer console max. 1000 W
•
operation mode: fan / warm/hot air
•
thermostat control
•
overheating protection
STRUCTURE (figure 1.)
Parts of the device:
1.
cold air inlet
•
2.
hot air outlet
3.
thermostat
•
4.
operation mode switch
•
5.
towel dryer console
•
6.
heating indicator light
•
7.
power cable
•
8.
wall console
•
9.
safety screw
•
10.
screws, studs
OPERATION
The device can be operated by using the rotary switch located on the side and with thermostat.
Functions of operation mode switch, without towel dryer console:
fan mode
I
1000 W heating stage
-
indicator light is on at the right side
II
2000 W heating stage
-
indicator lights both on right and left side are on
Functions of operation mode switch, with towel dryer console:
fan mode
I
fan mode
II
1000 W heating stage
-
indicator light on the left side is on
The
thermostat
(3) can be used to set the ambient temperature of the room. The appliance will switch on when the ambient air temperature falls below the adjusted. As soon as the set
temperature is reached, the unit will turn off. If you would like to set a higher temperature, turn the thermostat clockwise, if you want to set it lower, then turn it counter clockwise.
The
overheating protection
in the case of an overheating shuts down the device, e.g.: when the air entry or exit ports are covered. Unplug the device, by removing the power cord from
the socket. Let the device cool down (min 30 minutes). Make sure, that the air entry and exit ports are free, if necessary clean them. Setup the device again. If the overheating protection
activates again, unplug the device by unplugging the power cord and turn to a qualified service facility.
CLEANING, AND MAINTENANCE
1.
Switch off and power off the unit by unplugging it from the electric outlet before cleaning!
2.
Allow the appliance to cool (for at least 30 minutes).
3.
Clean the protective grill using a vacuum cleaner equipped with a brush accessory!
4.
Use a slightly moistened cloth to clean the unit’s outer surface. Do not use any aggressive cleaners. Avoid getting water inside of and on the electric components of the appliance!
TROUBLESHOOTING
Waste equipment must not be collected separately or disposed of with household waste because it may contain components hazardous to the environment or health. Used or
waste equipment may be dropped off free of charge at the point of sale, or at any distributor which sells equipment of identical nature and function. Dispose of product at a
facility specializing in the collection of electronic waste. By doing so, you will protect the environment as well as the health of others and yourself. If you have any questions,
contact the local waste management organization. We shall undertake the tasks pertinent to the manufacturer as prescribed in the relevant regulations and shall bear any
associated costs arising.
TECHNICAL SPECIFICATIONS
power supply: . . . . . . . . . . . . . . . . . . . . . 230 V~ / 50 Hz
output: . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000 W / 2000 W
maximum output without console: . . . . . 2000 W
maximum output together with console: . 1000 W
IP protection: . . . . . . . . . . . . . . . . . . . . . . IPX1: Protected from vertically dripping water!
size of heater without console: . . . . . . . . 31 x 41,5 x 11,5 cm
size of heater together with console:. . . . 37 x 69 x 11,5 cm
weight:. . . . . . . . . . . . . . . . . . . . . . . . . . . 2,5 kg
length of power cable: . . . . . . . . . . . . . . . 1,5 m
noise level: . . . . . . . . . . . . . . . . . . . . . . .
55
dB(A)
Solution
Check the information written at section about overheating.
Check the thermostat setting.
It is not default.
Clean the appliance
.
Malfunction
The unit is not working in heating stages.
Only one of the heating stages is operating together with the towel dryer console.
The overheating protection activates frequently
.