14
Copyright© 2017 SOMFY ACTIVITES SA. All rights reserved.
Axovia 220B RTS
EN
12.1. Connection to the solar power supply
Connect the solar power supply cable to the "BATT" terminal on the mo-
tor's electronic unit.
Ant
.
BU
S
Ce
ll
24Vd
c
13
5
7
9
11
24
6
8
10
12
Fl
as
h
M1
M2
B
a
tt.
MM
+
-
+
-
13
15
14
16
L
a
mp
230V
ac
+
-
1
2
3
+
-
2
1
3
12.2. Advice for use
If the gate is barred, we would suggest you protect the access to the arm
from the outside of the property.
In order to limit the energy consumption of your gate motor, we recom-
mend:
• the gate be closed to optimise the battery charge,
• the gate not be le open for more than 2 days,
• to activate automatic closing of the gate.
13. DIAGNOSTICS AND TROUBLE
SHOOTING
Attention
Power the installation off during cleaning or other maintenance
operations.
DIAGNOSTICS
TROUBLESHOOTING
The motors are
not responding
to remote con-
trol commands
The remote
control range is
reduced
- Check the remote control battery.
- Check the electronic unit aerial.
- Check that there are no outside
elements that are interfering with
the radio signal (electricity pylon,
metal reinforced walls, etc.). If
this is the case, fit an external
aerial.
Remote control
not stored
Store the remote control.
1 or 2 motors
unlocked
Lock the motors.
The control
unit's
=
=
indicator light
is off
Motor not
powered
- Check the power supply.
- Check the power supply cable.
Outdoor lighting
very low = motor
on standby
Increase the light around the elec-
tronic unit (e.g. using a torch) in
order to perform the settings (see
Ambient light detector below)
The control
unit's
=
=
indicator light
flashes:
DIAGNOSTICS
TROUBLESHOOTING
1 pulse
Operation
using the backup
battery
Check the mains power supply.
2 pulses
Motor awaiting
gate travel
self-program-
ming
Launch gate travel auto-program-
ming.
3 pulses
Cell fault:
- Cells blocked
Remove the obstacle blocking the
cells.
- Cells mis-
aligned
Correct their alignment (see in-
structions supplied with the cells).
- Cells incorrect-
ly wired
Wire the cells in accordance with
the instructions.
- Cells missing/
disconnected
- Check that the cells are correctly
connected.
- If you have deliberately discon-
nected the cells and your gate is
operating in automatic closing
mode, deactivate automatic
closing mode.
4 pulses
Short circuit on
the electronic
unit BUS output
(terminals 3-4)
Check the accessories connected
to the electronic unit's BUS output.
5 pulses
Electronics
thermal safety
activated
Allow the electronics to cool down
until the
=
=
indicator light comes
on continuously.
6 pulses
Short circuit on
the control unit's
24 V output
(terminals 5-6)
Check the accessory connected to
the electronic unit's 24 V output.
Short circuit
of orange light
(terminals 7-8)
on the control
unit
Check the wiring of the orange
light.
Motor short
circuit
Check the motor wiring.
Automatic clos-
ing mode is not
activated
(the
indicator light
stays off).
Photoelec-
tric cells not
installed
Install the cells (see instructions
supplied with the cells for instal-
lation).