7. ELECTRICAL CONNECTIONS
7.1. Cable guide fitting
Fit the cable guides on the two motors.
7.2. Connecting the motors
Motor M1 actuates the gate leaf that opens first and closes last, and opens
for pedestrian access.
1)
With the gate closed, identify the location of motor M1 by identifying
the gate leaf that will open first.
M1 est à gauche
OU
M1 est à droite
or
M1 is to the le
M1 is to the right
2)
Connect the motors as indicated in the table below.
• If M1 is to the le and M2 to the right
Motor
Wire
Terminal
M1
blue
9
brown
10
M2
brown
11
blue
12
• If M1 is to the right and M2 to the le
Motor
Wire
Terminal
M1
brown
9
blue
10
M2
blue
11
brown
12
7.3. Aerial wiring
For optimum performance, it is essential the aerial is correctly positioned.
Attention
Never cut the aerial wire.
Aerial
7.4. Mains cable connection
Connect live and neutral as per the following table.
Wire
Terminal
Blue
Neutral (N)
15
Red/brown/black
Live (P)
16
Green/yellow
Earth
12
M
2
Ba
tt
.
M
+
-
13
15
14
16
L
amp
230V
ac
Attention
Ensure the wire colours are observed.
Connect the power supply earth wire and the electronics earth wire (12) to
the motor clamp.
7.5. Locking the arms
1)
Close the two gate leaves and lock the arms by pressing them.
2)
Turn the motor locking handles to the locked position .
7.6. Switching the installation on
Switch the installation on.
The
=
=
indicator light on the electronic unit will flash (2 pulses) to indi-
cate that the motors are on and awaiting setting.
If the indicator light
=
=
does not come on, refer to the trouble shooting
guide.
8
Copyright© 2017 SOMFY ACTIVITES SA. All rights reserved.
Axovia 220B RTS
EN