“Functions” Menu Overview
9.1 Maintenance function “CH.SWEEP”
Call:
Position the pointer at the previous entry in the func-
tion overview: “CH. SWEEP: F:35” and press the rotary
wheel.
Description
: The burner is switched to continual mode
for maintenance or exhaust measurements using this
function.
The burner and the heating circuit pump are switched on
simultaneously when the pointer is positioned at “FUNC-
TION START” and you press the rotary wheel. You will also
see in the function overview under the entry “HEAT CIR.1”
the mode: “MAINTENANCE”. The run time of the burner is
then 20 minutes (unless an excess temperature protector*
switches off the burner beforehand). If this happens, you
must wait until the boiler has cooled down before you can
restart the function.
The “Status” menu line indicates whether this function
(the burner) is active. States: “ON” or “OFF”. You can
switch off the burner immediately by pressing the rotary
wheel at the pointer position “FUNCTION STOP”. After the
burner has been switched off, the heating circuit pump
remains switched on for a few minutes.
• “Tot. Runtime”
: Total runtime of the burner. The total run
time can only be changed from “Technician” operating
mode (or higher).
• “Burner perf.”
: The burner performance value can be set
from “Technician” operating mode (or higher), but this
does not affect the burner of the external boiler.
Menu, plain text
1 2 3 4 5 6 7 8 9 10 11 12 13 14
MAINTENANCE
FUNCTION START
— — — — — — — — — — —
DES.: CH.SWEEP
Status: OFF
Run Time: 0 min
Tot. Runtime: 10 min
Burner perf.: 100%
Maintenance function menu overview
9 “Functions” Menu Overview
All functions are briefly explained on
page 62f
. Menu
overviews of the most important functions are reproduced
in the following sub-sections. From the function overview,
(
page 11
) you receive the menu of the individual functions
when you position the pointer next to the number of the
function (e.g. “HEAT CIR.1 F:17”) and press the rotary
wheel.
_______________
* Safety mechanism protection function in the SolvisCon-
trol system controller: Turn off system at 98°C storage
tank temperature (top), restart possible at 80°C.
Status diagnosis at the controller
When the controller is in the “Technician” operating
mode, you can easily troubleshoot in the individual
functionsusing the “Function status” submenu.
A check mark next to a condition means that it
has been met (
page 49
).