P32-EN – Subject to technical changes 04.11
13
Client
Operating the System Controller
“HEAT. REQ.”: Setting the heating requirement:
Here you can set the “ECO mode”. The boiler will
remain off for a limited time, even though the room
temperature has not been reached. You will then
use more solar energy and save fuel.
Setting the ECO mode . . . . . . . . . . . . . . . . . . .
page 48
.
“WW_REQ.1”: Setting hot water heating:
• “REQUIREMENT: Status”
: Displays whether the hot water
requirement function is “ON” or “OFF”.
• “T.WW.NOM”
: Hot water target temperature, factory
setting 48°C, maximum value 55°C otherwise the plate
heat exchanger may show lime deposits.
• “TIME PROG”
: Calls the time menu for the auxiliary
heating of the hot water storage tank (factory setting:
Mo-Su: 24 hours; see also
page 17
)
set requested times, if necessary . . . . . . . . .
page 43
“WW_REQ.2”: Increasing the hot water supply
:
• “REQUIREMENT: Status”
: As with “WW_REQ.1”.
• “TIME PROG”
: By entering the standby times (factory
setting: Mo. – Su. deactivated) you can increase the hot
water supply if there is an increased demand.
page 44
“CIRCU”: Setting the circulation circuit
• “TIME PROG”
: Open the circulation times menu. (Factory
setting: Mo-Su: 24 hours;
page 17
)
set requested times, if necessary . . . . . . . . . .
page 46
“WW_REQ.3”: Setting the swimming pool heater:
• “T.WW.ACT”
: Actual temperature, swimming pool.
• “T.WW.NOM”
: Nominal swimming pool temperature,
factory setting 30°C.
• “TIME PROG”
: Calls the time menu for the auxiliary
heating of the swimming pool (factory setting: Mo-Su:
deactivated)
set required times, if necessary . . . . . . . . . . .
page 45
“HQC SOLAR”: Heat quantity counter solar circuit
To use this function, a volume flow measuring unit
(
section 4.3, next page
) must be installed in the
secondary solar line.
• “POWER”
: Current heat output in kW.
• “HEAT QUANTITY”
: Infed heat in kWh.
• “FLOW”
: Volume flow in l/h.
• “T.Pre-run”
: Flow temperature in solar circuit in °C.
• “T.return”
: Return temperature in solar circuit in °C.
“FLOOR DRY”: Floor drying heating program
for heat circuit 1. . . . . . . . . . . . . . . . . . . . . . . .
page 59
Maintenance function
:
• “CH.SWEEP”
: Test operation of the burner, e.g. for
measuring exhaust gases. . . . . . . . . . . . . . . .
page 32
— — — — — — — — — — —
HEAT. REQ
F:21
— — — — — — — — — — —
WW_REQ.1 F:10
REQUIREMENT:
Status: OFF
T.WW.NOM: 48°C
TIME PROG:
— — — — — — — — — — —
WW_REQ.2 F:11
REQUIREMENT:
Status: OFF
TIME PROG:
— — — — — — — — — — —
CIRCU
F:16
TIME PROG:
— — — — — — — — — — —
WW_REQ.3 F:23
T.WW.ACT: 30°C
T.WW.NOM: 30°C
TIME PROG:
— — — — — — — — — — —
HQC SOLAR
F:30
POWER: 0.00
kW
HEAT QUANT.:
0.0 kWh
FLOW: 0
l/h
T.Pre-run: 65°C
T.return: 38°C
— — — — — — — — — — —
FLOOR DRY
F:22
NOM. VALUE:
5°C
— — — — — — — — — — —
CH.SWEEP
F:35
FUNCTION START
HELP
SERVICE