CIE-H14 User Manual Ver. 1.1

 

 

- 61 - 

http://www.ezTCP.com

 

 

8.3.4 

TX interval - 

 

This option is for preventing data loss in the case that the serial device has very small 

buffer size or does not have a buffer. The range of the value could be from 0 to 25 and the 
unit is duration of sending 1 byte. For example, if you set this value to 5, each byte will be 
transferred with duration of sending 5 bytes. 

8.3.5 

TCP Server / Client mode - 

 

This mode is available on TCP client mode only. In this mode, you do not need to change 

the mode for switching active or passive TCP connection. Note that the [Event Byte] option 
should be set to 1 or lager value. 

8.3.6 

Separator - 

 

Using this function, you can control the length of network packets by specific characters. 

separator 

options 

Length 

select the length between 0 ~ 4 bytes 

Operation 

Transmit Separators without additional bytes 

Transmit Sepa 1 byte 

Transmit Sepa 2 bytes 

Table 8-2 separator 

 

 

If you want to get more information about the above functions, refer to the technical 
documents on the [Download] >> [Technical documents] page at our web site.

 

 

 

 

Summary of Contents for CIE-H14

Page 1: ...Sollae Systems Co Ltd http www ezTCP com 4 ports Remote I O Controller CIE H14 User Manual Version 1 1...

Page 2: ...nsuring this product is disposed of correctly you will help prevent potential negative consequences to the environment and human health which could otherwise be caused by inappropriate disposal of thi...

Page 3: ...rt DB9M 14 1 6 5 Ethernet Interface 15 1 6 6 System LED 16 1 6 7 ISP Switch 17 2 Installation and Test 18 2 1 Installation 18 2 1 1 Setting Network Aera 18 2 2 Test operation 20 2 2 1 Modbus TCP Test...

Page 4: ...CP Master Mode 30 5 1 4 TCP Connection Modes 31 5 1 5 Initial Output Value 31 5 1 6 Write Pulse 31 5 2 Serialized Modbus TCP 31 5 3 Macro Mode 32 5 3 1 Operator 32 5 3 2 Operand 32 5 3 3 An Example of...

Page 5: ...hange 57 8 2 2 Sending MAC Address 58 8 2 3 Debugging Message 58 8 3 Serial Port Tab Functions 60 8 3 1 TELNET COM port Control Option RFC 2217 60 8 3 2 Disable TCP Transmission Delay 60 8 3 3 Data Fr...

Page 6: ...11 1Technical Support 68 11 2Warranty 68 11 2 1 Refund 68 11 2 2 Free Repair Services 68 11 2 3 Charged Repair Services 68 12 Precaution and Exemption from Liability 69 12 1Precaution 69 12 2Exemptio...

Page 7: ...Modbus TCP serialized Modbus TCP and Macro mode can be used for these functions CIE H14 is additionally equipped with a RS232 serial interface to allow your serial devices to establish an Ethernet ne...

Page 8: ...ual Ver 1 1 7 http www ezTCP com 1 3 Application Examples Remote I O device server Figure 1 1 remote I O device server Serialized Modbus TCP Figure 1 2 serialized Modbus TCP Internet Switch Figure 1 3...

Page 9: ...CIE H14 User Manual Ver 1 1 8 http www ezTCP com Serial Switch Figure 1 4 serial switch Macro mode Figure 1 5 macro mode Serial Device Server Figure 1 6 serial device server...

Page 10: ...CIE H14 User Manual Ver 1 1 9 http www ezTCP com 1 4 Components CIE H14 RS232C Cable for PC option Dry contact adaptor option...

Page 11: ...85 Certification KC CE FCC Environment Follows Europe RoHS Directive Table 1 1 H W specification 1 5 2 S W specification Protocol TCP UDP IP ICMP ARP DHCP DNS lookup DDNS SMTP Telnet COM Port Control...

Page 12: ...CIE H14 User Manual Ver 1 1 11 http www ezTCP com 1 6 Interface 1 6 1 Power The Power is interfaced with a 5mm terminal block and DC 8 5 38V polarity auto detection is allowed Figure 1 7 Power...

Page 13: ...t Voltage DC 24V Polarity Auto Polarity Table 1 3 the voltage specification of the input ports The input port is interfaced with a 5mm terminal block Thus use a shaped screwdriver to connect it with t...

Page 14: ...F open 1 ON short Table 1 4 values of the output port The allowed output ports electrical current of voltage conditions are as in the following Voltage Condition Allowed current DC 28V 5A Table 1 5 vo...

Page 15: ...RS232 Input required 3 TXD Transmit Data RS232 Output required 4 DTR Data Terminal Ready RS232 Output option 5 GND Ground Ground required 6 DSR Data Set Ready RS232 Input option 7 RTS Request To Send...

Page 16: ...t items RTS DTR Baud rate data bits parity stop bit after getting information from the communication counterpart 1 6 5 Ethernet Interface An RJ45 connector is for the network interface of CIE H14 You...

Page 17: ...nnected with 10Mbits link RJ45 Green On connected with 100Mbits link Common Serial RXD Blinks receiving data from the Serial TXD Blinks transferring data to the Serial Normal mode STS Blinks every sec...

Page 18: ...go into the serial configuration mode that you can configure the environment parameters through the RS232 port If you press it over a second or supply power while pressing it CIE H14 will be operated...

Page 19: ...t port to a PC It will be no problem if the Ethernet connection is established through network hubs Figure 2 1 the connection between CIE H14 and a PC 2 1 1 Setting Network Aera This step is for setti...

Page 20: ...ers are listed on the table below To do the following simple test keep these values during the test parameter value Network Local IP Address 10 1 0 1 Subnet Mask 255 0 0 0 Option Telnet Checked IPv4 A...

Page 21: ...ruction offered Modbus TCP test program was used Run ezManager Then you can see the window as shown below Figure 2 3 Modbus TCP test program of the ezManager Search connected CIE H14 with Search All b...

Page 22: ...the local port for Modbus TCP of CIE H14 In a local area network and steps can be omitted Try to connect by pressing Connect button Under the connection check if the Di LEDs are turned on or off with...

Page 23: ...Input the IP address of your CIE H14 on the address field Ex 10 1 0 1 Check if DI LEDs are turned on or off with HIGH signal Check if DO LEDs are turned on or off with clicking the each of LEDs Press...

Page 24: ...al appearance of ezManager 3 1 1 Configuration via LAN Checklists Make sure of the connection between your PC and CIE H14 via Ethernet If they are in the same network MAC Address search button can be...

Page 25: ...serial configuration mode by pressing the ISP button less than 1 second After then read the setting on the Serial tab Procedures Figure 3 3 procedures for configuration via serial port Step 2 Reading...

Page 26: ...an change some parameters through the serial port Figure 3 5 setting the communication mode to the AT command Procedures Figure 3 6 procedures for configuration with AT command Division Available para...

Page 27: ...able in this mode Serial configuration mode This mode is for configuring environmental parameters through the RS 232 port ISP mode This mode is for upgrading firmware and HTML files In addition you ca...

Page 28: ...IE H14 via Modbus TCP It supports both master and slave mode Serialized Modbus TCP CIE H14 communicates through the RS232 port using the data format of Modbus TCP Macro Users can automatically control...

Page 29: ...or security like filtering with password or MAC and IP addresses In the Serial Configuration mode you can revoke all of these options When you forget the password enter this mode to change or delete i...

Page 30: ...n Active Connection requesting a Modbus TCP connection Multiple Connection The numbers for multiple Modbus TCP connections Control Method of FC XX Control method for the output ports of the slave Sing...

Page 31: ...t Port Base Address 5 1 3 Modbus TCP Master Mode In this mode CIE H14 operates as a Modbus TCP master As a master CIE H14 transmits its input information to the salve and outputs the slave s input val...

Page 32: ...host are required Table 5 3 the passive active connection 5 1 5 Initial Output Value The initial value of CIE H14 s output port can be configured The output ports are set to ON or OFF according to th...

Page 33: ...thesis NOT AND OR Each operator is represented by the following symbols name sign description Parenthesis Since calculations within the parenthesis have the highest priority they will be calculated fi...

Page 34: ...e expression within the parentheses i1 i2 is evaluated first and then the value is toggled due to a NOT operator This result is used to perform an AND operator with i0 Table 5 5 an example of equation...

Page 35: ...er name is not required Leave blank or put a random name Password should be the same with a password which is set through the ezManager 5 4 1 Changing port number for HTTP In case you cannot use the p...

Page 36: ...function is available to anyone who can make HTML files If you get some simple syntax it is possible to monitor and control the I O ports with your homepage interface For more details about this pleas...

Page 37: ...rt number which is used in the TCP connection Event Byte With setting event bytes users can handle the serial data before a TCP connection is established Value Description 0 CIE H14 does not send the...

Page 38: ...TCP server Figure 6 1 TCP server Point State CIE H14 is waiting for request segments of a TCP connection Remote host has sent a request SYN segment Processes of the connection The connection has been...

Page 39: ...TCP connection with this parameter Value Description 0 CIE H14 sends a request segment of the TCP connection right after it boots up Otherwise 512 or under CIE H14 sends the segment right after it re...

Page 40: ...re 6 2 time chart Point State Before the power is supplied Sends request segments of a TCP connection right after it boots up Processes of TCP connection The connection has been established Data commu...

Page 41: ...ver option Point State CIE H14 listens to connection requests The connection has been established CIE H14 is online and processes of the disconnection The connection is terminated Both sides are offli...

Page 42: ...at plp 1470 CR prip Peer IP Address at prip 10 1 0 2 CR prp Peer Port at prp 1470 CR pdc DHCP at pdc 1 CR On pto Timeout at pto 10 CR pwp Store setting at pwp CR Table 6 7 some of extended commands f...

Page 43: ...H14 waits request segments of a TCP connection with the ATA command CIE H14 is waiting for requests of a TCP connection A remote host has sent SYN segment to CIE H14 Processes of the TCP connection TC...

Page 44: ...Point State Set parameters in the AT command mode CIE H14 sends a request segment of a TCP connection with the ATD command Processes of the TCP connection The TCP connection has been established CIE...

Page 45: ...ne block to the network The value is up to 1460 bytes Data Frame Interval Data Frame Interval means the time for gathering data to make them into a block Its unit is 10ms If there is no transmission f...

Page 46: ...me Interval is 100 1s Point State CIE H14 is receiving data from the serial port CIE H14 Sends 5 bytes as one block based on the Block Size Serial device sends data 678 to CIE H14 Data 678 has arrived...

Page 47: ...6 11 setting for dynamic update of peer host function Figure 6 7 Time chart for dynamic update of peer host Point State Sending any UDP data to the network is impossible UDP data arrives from Remote H...

Page 48: ...are file We update our homepage when a new firmware is released You can find it on our website Entering ISP mode Enter ISP mode to download firmware file to CIE H14 Run a TFTP client and ready to send...

Page 49: ...nual Ver 1 1 48 http www ezTCP com Checking firmware file and Sending Figure 7 2 sending firmware file Check if the name and path of the firmware file are correct Click the Send button Confirm the com...

Page 50: ...TTP 7 2 2 Processes Making Users webpage or Downloading sample files Make your own webpage file or use sample webpage files freely available to download at our web site Entering ISP mode Enter ISP mod...

Page 51: ...is equipped with the client program Click the Change F W HTML button Figure 7 4 running TFTP client Check the Advanced Menu check box Click the Change F W HTML button to run TFTP client Select the Ch...

Page 52: ...User Manual Ver 1 1 51 http www ezTCP com Checking files and Sending Figure 7 5 sending firmware file Check if the name and path of the files are correct Click the Send button Confirm the completed m...

Page 53: ...hat messages from CIE H14 appear as shown in the figure below Figure 7 6 log in to CIE H14 on TELNET You can check multiple states with the following commands command option description usage st net N...

Page 54: ...nd st uptime st uptime command shows amount of time since CIE H14 has booted up Figure 7 9 st uptime command sc sc command is used when users close a session OP1 means the name of session and OP2 shou...

Page 55: ...is automatically updated in every second Figure 7 12 status window of ezManager FIRMWARE VERSION The name of model and the version of firmware are displayed here SYSTEM UPTIME Operating time of CIE H1...

Page 56: ...s HIGH ON and 0 means LOW OFF ARP TABLE This part shows ARP table on CIE H14 When a TCP connection is established or UDP data communication is performed the information of IP and MAC address is automa...

Page 57: ...ples IP Address Network Mask Allowed IP Address Range 10 1 0 1 255 0 0 0 10 1 0 1 10 255 255 254 10 1 0 1 255 255 255 0 10 1 0 1 10 1 0 254 192 168 1 4 255 255 255 255 192 168 1 4 Table 8 1 examples o...

Page 58: ...and create host names on the website of DynDNS before use this All about service usage of an account could be changed according to the policy of DynDNS Homepage of DynDNS http dyn com dns Figure 8 1 s...

Page 59: ...receive debugging messages from CIE H14 on the network When you are facing a problem about the TCP connection or data communication use this function and send us the stored file We can use it for fin...

Page 60: ...messages from CIE H14 over the network Auto update to display the latest captured file on the screen of MAC Address Information of a selected message Unavailable To start capturing debugging messages...

Page 61: ...are changed 8 3 2 Disable TCP Transmission Delay If you use this option CIE H14 sends the data from the serial port to Ethernet as quickly as possible 8 3 3 Data Frame Interval Before sending data fro...

Page 62: ...le on TCP client mode only In this mode you do not need to change the mode for switching active or passive TCP connection Note that the Event Byte option should be set to 1 or lager value 8 3 6 Separa...

Page 63: ...Change When input or output port is changed you can receive an email for notification from CIE H14 using SMTP protocol When ports you selected are changed status of CIE H14 is sent to the Email addres...

Page 64: ...ver because the accuracy is only guaranteed in 10ms the designated values are rounded down in units of 10ms 8 4 3 Delay Output values are reflected to CIE H14 s output ports later than the time set to...

Page 65: ...programs have firewall functions so it can cause some trouble to search CIE H14 Close or pause these programs before searching the product Stable supply of the power Check if the power is supplied con...

Page 66: ...eed strong security the access may be denied by their firewall Under this circumstance users should ask the person in charge of their network to release ports which will be used Ex TCP 502 UDP 50005 O...

Page 67: ...ated parameters that Unit ID Input Port Base Address Output Port Base Address Poll Interval and Notify Input change Checking which mode is using In case of MACRO or serialized Modbus TCP you can contr...

Page 68: ...bus TCP protocol Internet switch Serial switch Combinations of I O Controllers Digital Pulse Output Dry Contact Adapter DCA How to use a user s homepage IP Change Notification DDNS Sending MAC Address...

Page 69: ...customer s request to refund the product within two weeks after purchase Sollae Systems will refund the product 11 2 2 Free Repair Services For product failures occurring within 2 years after purchase...

Page 70: ...applications provided by Sollae Systems for purposes other than those for which they were designed is prohibited Do not use the product in an extremely cold or hot place or in a place where vibration...

Page 71: ...n financial losses damage to property personal injury or the death of people or animals If you use the CIE H14 voluntarily or involuntarily for such unauthorized applications you agree to subtract Sol...

Page 72: ...voiture camion train avion etc ni en milieu explosif ni dans des enceintes nucl aires ni dans des ascenseurs ni dans des a roports ni dans des enceintes hospitaliers ni pour des applications caract r...

Page 73: ...nts lectroniques usag s Le symbole de la poubelle barr pr sent sur le bo tier CIE H14 indique que vous ne pouvez pas vous d barrasser de ce dernier de la m me fa on que vos d chets courants Au contrai...

Page 74: ...CIE H14 User Manual Ver 1 1 73 http www ezTCP com 13 History Date Version Comment Author 2013 08 21 1 0 Initial Release Amy Kim 2014 01 15 1 1 Add comment of Users Web Page document Amy Kim...

Reviews: