background image

 
 

 

5

   

2. MANUFACTURER'S WARRANTY

 

 

WARRANTY ON PRODUCTS IN THE SERIES 

Sunsys pro 

 

Sicon S.r.l., part of the group that deals with Socomec, control and security of electricity grids in low voltage, with registered 
office in Silas 1/3 - Z I. Scovizze, Isola Vicentina 36033 Vicenza (VI), warrants its products in the series 

Sunsys pro

 are 

new and meet both the specifications and such regulations as applicable. 
 
Terms of warranty 

Sicon S.r.l. warrants its products Sunsys pro series for a period of 5 years from their purchase only to defects in 
manufacture or materials. 
The period of validity of this guarantee is calculated from the date of purchase of the new product by the end user at a 
official dealer (by the date stated on the purchase document). This warranty is valid only for products installed in Italy. 
 

The warranty includes: 

a)  repair or replacement of the defective product or component, but with shipping and installation of the product or 

component replacement by the customer or end user; 

 

b)  sending to Sicon S.r.l. (Or any authorized service centers) with removal of the defective product, transportation 

and related fees customer or end user. 
The decision to repair or replace the defective product or component will be responsible solely and exclusively to 
Sicon S.r.l. 
The replacement of parts, repair parts, modifications, or components of the product during the warranty period is 
not prolong the duration of the warranty.The standard warranty is additional and not in lieu of any other rights 
enjoyed by the consumer / purchaser of the product and, in particular, without prejudice to the rights that the 
consumer is the holder pursuant to Legislative Decree 06.09.2005 n. 206 (cd.Consumer Code). Sicon S.r.l. 
reserves the right to offer extensions of this warranty to be agreed in writing. 
 

Procedure. 

1.  Defects must be reported to the Department of the Post-Sale of Sicon Photovoltaic Ltd (By Silas 1/3 - Industrial 

Zone Scovizze 

– Isola Vicentina 36033 Vicenza - Vi -) 800.00.80.85 toll free or in writing by registered mail or 

([email protected]) or fax (0444-598626).In every case must be immediately provided to the 
Department predicted a brief written report indicating the type of defect, product serial number and all data 
contained in the same nameplate. 
In the written report must be accompanied by a copy of proof of purchase (document - note, invoice, sales slip tax 
- indicating the date of purchase and which should include the necessary data for identification of the product - 
model, serial number -). In case you can not provide such proof of purchase, will use the serial number and date 
production to calculate the expiration of the warranty. The defective product will be returned to Sicon Srl only after 
obtaining the return authorization number which will be released from service centers after receipt of notice of 
defect. 

2.  The defective product must be returned to Sicon Srl in the original or equivalent, attaching the authorization 

number the return. 

3.  Where assets are recognized and pampered under warranty, Sicon Srl will send the product and / or the 

component fixed to or in place end user at the address notified by them together with the reporting defects or, 
failing that, at the place where / the good / s have been delivered as specified in the contract of sale. 

4.  The shipment of the product and / or component replacement is the responsibility of Sicon S.r.l. 
5.  The installation of the product and / or component replacement should be performed by qualified personnel or by 

a service center authorized and the cost thereof shall be borne by the customer or end user. 

6.  All activities performed by Sicon S.r.l. of products and / or components not under warranty, shall be paid at Sicon 

S.r.l. in accordance with the rates and conditions normally applied by itself. 

7.  Sicon S.r.l. reserves the right to provide a different model of product and / or component provided equivalent 

performance in the case where the original model - spoiled and warranty - is out of production. 

8.  In case of request for on-site staff that Sicon Srl, the costs of intervention and the cost of moving the Staff will be 

charged to the customer / end user at the rates Sicon Srl force. 

Summary of Contents for SUNSYS - B10

Page 1: ...SUNSYS B10 Installation and Operation Manual ...

Page 2: ...ead this manual carefully In case you encounter any difficulties during installation or use of the device consult the manual before contacting your dealer or local representative Thanks again for choosing our product Keep this manual handy for quick reference Begin to enjoy Sunsys B10 and pro life SOCOMEC owns the rights to full and exclusive ownership of this document The recipient of this docume...

Page 3: ... 4 2 MANUFACTURER S WARRANTY 5 3 GENERAL DESCRIPTION 7 5 INTALLATION INSTRUCTION 12 6 OPERATION OF PV INVERTER 22 7 INVERTER OPERATING STATUS 35 8 COMUNICATIONS 43 9 TROUBLE SHOOTING 44 10 PREVENTIVE MANTENANCE 48 11 SPECIFICATION 51 ...

Page 4: ... th he e p po ow we er r i is s d di is sc co on nn ne ec ct te ed d PUBLIC UTILITY ONLY T Th he e P PV V i in nv ve er rt te er r i is s d de es si ig gn ne ed d t to o f fe ee ed d A AC C p po ow we er r d di ir re ec ct tl ly y t to o t th he e p pu ub bl li ic c u ut ti il li it ty y p po ow we er r g gr ri id d D Do o n no ot t c co on nn ne ec ct t t th he e A AC C o ou ut tp pu ut t o of f ...

Page 5: ...ree or in writing by registered mail or Assistenza socomec com or fax 0444 598626 In every case must be immediately provided to the Department predicted a brief written report indicating the type of defect product serial number and all data contained in the same nameplate In the written report must be accompanied by a copy of proof of purchase document note invoice sales slip tax indicating the da...

Page 6: ...ich the product and or component is not vitiated returned to Sicon Srl in the original packaging or equivalent II in the case where the serial number identification of the products has been manipulated or not it is uniquely identifiable III in the case in which the defect relates to aspects relating to the aesthetics or construction of small entities that do not compromise the normal functionality...

Page 7: ...ace and a connection to the Public Utility The typical connection diagram of the PV system is shown in the following figure 2 1 SUNSYS B10 presentation SUNSYS B10 grid tied PV Inverters converts direct current DC power generated by PV modules into alternating current AC which is compatible with the local electricity distribution network also called the public utility or grid system ...

Page 8: ...10 Grid tied PV inverter shows the rating label of the Inverter The rating label states the Type Brand Name Model Name Specifications and the Serial Number of the Inverter When encounter any difficulties during installation or operation please record the Serial Number SN before contacting your local dealer or representative ...

Page 9: ...l communication slot 4 Pressure Compensation Seal A hardware device that used to dissipating heat into the surrounding air 5 USB Interface Connect this port directly to your PC via an USB cable users can communicate with the Inverter through specific program tool 6 AC Output Cable Gland For wiring AC output cable to the grid with a waterproof enclosure 7 Ground PE Cable Gland For wiring Ground PE ...

Page 10: ...Each I P power O P power Operation mode and warning message Storage Period 5 years Storage Media 2GB SD card support up to 32GB Data Download Via B type USB 3 3 2 Features of Graphic Data Logger Multicolored back light The backlight of the LCD will be changed according to its status There are 3 colors of backlight and their indications are Green Start up and normal status Red Fault Status In this ...

Page 11: ... convert the maximum power from any PV panel Due to its advanced design this PV inverter can track the maximum power from the PV panel in any condition When the displayed power on the LCD output does not change dramatically the Inverter is converting the maximum power from panels When the LCD power reading is significantly changes the Inverter is tracking the power according to the varied sunlight...

Page 12: ...ce conversion efficiency Check the ambient temperature of installation is within specified range 20 60 C The grid voltage and frequency at installed site must be within the specific range defined by applicable regulation type Electric utility company has approved the grid connection Only qualified personnel are performing the installation and maintenance Adequate convection space surrounds the Inv...

Page 13: ...rom each other Note Don t mount PV inverter on top of another one or other heat radiating sources unless it is inevitable in that case 100cm spacing at minimum from each other is required to provide proper ventilation effect A Fix the Bracket by using all of six mounting holes the bracket should be fixed with M5 30mm screws by 30kgf cm or 2 94 N m torque force as illustrated below Notes Diameter f...

Page 14: ...14 location when the hanging irons installed on the PV inverter as illustrated Notes Proper lifting tool must be used for the lifting please beware C Mount the Inverter onto the bracket as illustrated ...

Page 15: ...15 D Check and ensure the device is properly fixed to the bracket in the proper direction ...

Page 16: ...mm 2 2 Remove the rubber plug from inside of the AC connector socket 3 Insert all AC wires through AC cover kit in following order before cramped with insulated cord end terminal cable gland rubber bushing AC cover cord end terminal 4 Connect the AC wires to the AC terminal block correspondingly and tighten it properly PE2 wire area must be of same gauge as PE1 does or 10 mm 2 5 Add an insulated c...

Page 17: ...r 7 Twist the connector cable gland to lock the bushing and cable together firmly 8 Check the installation condition again Do not install the PV inverter on a slanted surface Check Inverter are securely hooked on bracket at both of upper and lower sides ...

Page 18: ...vice before connecting of PV module To obtain optimal result from PV inverter please consider the following guidelines before connecting the PV modules to the device 1 Firstly make sure the maximum open circuit voltage Voc of each PV string does not exceed the related specification as below table listed in all condition 2 Check short circuited current of the PV string The total short circuits curr...

Page 19: ...he connector slightly downward to disassemble the DC cable Warning D Do on n t t d di is sc co on nn ne ec ct t D DC C p po ow we er r o or r c ca ab bl le es s w wh hi il le e t th he e I In nv ve er rt te er r i is s s st ti il ll l f fe ee ed di in ng g A AC C p po ow we er r t to o t th he e g gr ri id d b be e s su ur re e t to o s sw wi it tc ch h o of ff f A AC C p po ow we er r a at t f fi...

Page 20: ...between the PV inverter and the public network The value of this switch recommended 32 A 400V 4 poles must be designed by a qualified technician in order to meet the local safety regulations Is also recommended the use of a differential switch type A AC value of 300mA ...

Page 21: ...AC grid is not connected to the Inverter the Data Logger LCD displays the following Pac 0W Temperature 26 8 C Iac 0 0 0 0 0 0A Vac 0 0 0 0 0 0V Status Fault No Utility 21 04 12 15 01 3 Check the connection between PV inverter and the AC Connection System and then check the connection between the Public Utility and the AC Junction Unit Close the AC breaker or fuse in the unit 4 Under normal operati...

Page 22: ...rectly at both DC input and AC output This operation is very delicate since due to problems of yield it is possible to run only once in case of error you must contact Socomec service center At first time them Will be given the opportunity to choose the country from several European countries Selecting them by using the arrows e Identified the country desired press the OK key after which they will ...

Page 23: ...dium voltage Then is necessary to set the inverter parameters 1 Default the parameters are the default parameter specified in the regulatory of the contry selected 2 Customization All parameters are settable in accordance with the regulatory of the country selected if it is set cusomization in subsequent windows will be set one by one all the parameters For accept press OK At the end of all settin...

Page 24: ...Automatic start The PV inverter starts automatically when the DC power from the photovoltaic field is sufficient to run only after the initial startup Regulation Parameter FH D BACK 50 10Hz FL D BACK 49 90Hz Freq L1 Disable Power Reduction 2 4 Power VS Freq Enable Reconnection T 300s Yes No Green backlight ...

Page 25: ...klight will be yellow as following picture If there is no further abnormal event after 48 hours of operation the color switches back to green again Pac 7494W Vdc 403 420V Vac 230 5 232 3 231 1V Iac 10 5 11 2 10 7A Status Normal 21 04 12 15 01 3 During Fault During grid fault or system failure refer to error message table for further information the Inverter disconnects from the grid the backlight ...

Page 26: ...nverter keeps checking both DC and AC conditions and waiting for connection Pac 0W Vdc 260 329V Vac 219 4 219 3 219 3V Temperature 26 8 C Status Waiting 21 04 12 15 01 Normal To be in Normal state voltage on DC side must be 350V or above To check the DC wire connection this Inverter tries to disturb its input power for every starting up During the process user can see the DC power reading drift Pa...

Page 27: ...ure or error occurs other than the backlight goes red the backlight flashes every second until user presses the key accordig to instruction on the LCD 3 Audio Alarm To inform the user data logger will emit audio alarm in cases of following a Inverter failure b Memory capacity of data logger is less than 5 remained c Convection fan is not able to rotate for any reason This audio alarm can be disabl...

Page 28: ...d date On occurrence of a warning or error message the bottom line Status is automatically replaced by the error message The user can change the four monitoring parameters a Press to highlight the monitoring parameter at the first line By using and the user can shift to the next line b Press OK to begin setting the monitoring parameter c Press or to select the monitoring parameter of the line d Pr...

Page 29: ... power during 6 minute interval each dot means 500W the maximal dot number is 48 Date On the upper right corner the date of present display is shown To see daily graph of expected day press and to select 6 12 9 7 8 10 11 1 2 3 4 5 20 KW 20 04 10 4 Weekly graph Press the of daily display LCD changes to the Weekly Display as below For further explanations see below Time axis x axis 7 days from Sunda...

Page 30: ...as shown below System Display S N 0123456789ABCDEF Version MB 20 00 27 Memory 0 3 Date 21 04 2011 Sat Time 15 01 19 GMT 08 Audible Alarm On Language English The following are the monitoring parameters shown in System Display S N Serial number of the Inverter Version Firmware version of the Inverter Memory Memory status of the Data Logger Date Date setting of the Inverter Time Time setting of the I...

Page 31: ...ssword 4613 to set all parameters again See Grid Parameter settings at point 6 1 for more details 8 Reactive power function When is pressed again appears the Reactive Power Function screen By pressing the OK keys for 10 seconds and by insert a password 4613 is possible to choose a method of managing the reactive power or if it is already active is possible to disable it Password Select char Delete...

Page 32: ...er of constant power factor function Select the desired value by pressing o and confirm pressing OK 3 Const Q by pressing OK is possible to set the parameter of constant reactive power function Select the desired value by pressing o and confirm pressing OK 4 Curve PF P by pressing OK is possible to set the parameters of curve of management of the power factor in function of active power Reactive P...

Page 33: ...wer in function of grid voltage Select the desired value by pressing o and confirm each value pressing OK The item in the Power Factor Curve setting page are refer at the following picture Power Factor Curve With Power Percent V lock in 241 4V V lock out 230 0V Node 1 20 1 00pf Node 2 40 1 00pf Node 3 50 1 00pf Node 1 100 0 90pf Q Curve VS Voltage Type A P lock in 20 Pn P lock out 5 Pn Node 1 90 4...

Page 34: ...Limit 100 Pn 9 Active power function From the screen Reactive Power Function by pressing again switches to Active Power Func In this screen are only show if it is enable and the value of a possible limitation of active power ...

Page 35: ... friendly the status of the Inverter can be easily understood by reading the information shown on the front panel display or through remote monitoring All possible messages are listed in the following table The Language Matrix of Display Messages Continue in next page ...

Page 36: ...36 ...

Page 37: ...37 ...

Page 38: ...38 ...

Page 39: ...39 ...

Page 40: ...40 ...

Page 41: ...41 ...

Page 42: ...42 ...

Page 43: ...ich allows user to use to monitor the real time status of multiple Inverters Firmware upgrade is also conducted via this interface Connecting laptop PC to Inverter via USB type A to type B adapter cable 8 2 SB Interface Data Logger The Data Logger is fit with a B type USB connector for your PC USB host interface Open the USB socket cover before use ...

Page 44: ... turn off the AC switch 2 Disconnect the DC side from the Inverter 3 Check both the AC and DC wiring and insulation 4 Reconnect AC DC connection check the status of Inverter 5 If the problem persists please Update the firmware according to instructions or Replace the Inverter Notes An insulation gloves must be wearing during procedures Isolation Fault The ground current detected by Inverter is hig...

Page 45: ...operated normally 2 If problem still occurred check the reading value of AC grid from the LCD display of Inverter 3 If reading value is within specification check the system connection including polarities and security first 4 Find the devices with high power consumption near the AC system 5 Consult the utility power supplier understand the grid conditions regarding the local grid code 6 Use Inver...

Page 46: ...n LCD reconnect the DC again and check 4 If the fault message still appears again after restart call your local service 1 Make sure installation is configured under specification 2 Processes the same actions again as left column mentioned 3 If the problem still persists please try to Upgrade the latest firmware according to instruction or Replace the unit DC INJ High The detected DC current of Hal...

Page 47: ...inues Update the firmware according to instructions or Replace the Inverter Low DC Bus DC voltage of DC inside Inverter is lower than expectation DC Input voltage that feed to DC BUS is too low DC Sensor Fault The DC sensor at output is abnormal 1 Operation firmware is Abnormal 2 Detected current of Hall sensor is abnormal 1 Disconnect PV and PV from the input start the unit again 2 If it does not...

Page 48: ... rid of it if find any 2 Check heatsink to ensure no barrier blocking its air flow 3 Inspect for corrosion especially at connecting point 4 Verify all connections are firmly tightened periodically 5 Clean the exterior of the unit periodically with a damp cloth to prevent Inverter from accumulation of dust and dirt Keep warranty label intact anyhow 6 To get optimal performance PV modules cleaning p...

Page 49: ...e procedures of fan module for the SUNSYS B10 model 1 Disconnect the AC power and the DC power of PV inverter 2 Unfasten all the screws of fan module as figure indicated below 3 Take off the fan module by disconnect its cable adapter as figure indicated below 4 Clean fan with damp cloth or soft brush tenderly if needed ...

Page 50: ...odule is damaged or malfunctioned permanently please make a replacement by a new fan module 6 Assemble the fan module in the reverse order of above procedures 7 Check Inverter resumes normal operation after restart ...

Page 51: ...ower 10500W Maximum DC current 16A 2 Max number of parallel strings 2 2 External DC Circuit Breaker 20A x 2 Max Inverter Backfeed Current to the PV Array 300mA DC insulation resistance 1 2 M DC insulation Transformerless Output AC Nominal AC power 10kW 10kVA Max AC power 10kW 10kVA Nominal AC current 14 5A Max AC current 16A Current Inrush 65A Max Output Fault Current 30A AC Max Short Circuit Curr...

Page 52: ...emperature range 20 60 Continuous Output power temperature range 20 45 Max O P power 60 0 C nominal voltage linear de rating 10000W Max Operating Temp without derating for nominal voltage 45 0 C Humidity 100 condensing Altitude Up to 2000m without power derating Hazard substance restriction Lead free complied with RoHS GP2 Ground fault protection Internal RCMU and Isolation detection function DC d...

Page 53: ...6 3 2007 A1 2011 DC Switch Optional EN 60947 1 EN 60947 3 CE LVD 2006 95 EC EMC 2004 108 EC 11 2 Load Graphs Load graphs are the typical efficiency charts that related to VDC and PAC is and the output power within the operation range can be determined by the different level of input voltage as power curve that shown in the following ...

Page 54: ...54 ...

Reviews: