3.3. Introduction of Graphic Data Logger
To show the information of Inverter, there is a graphic Data Logger in the unit. This Data Logger can show
various information of the Inverter such as operational status and warning message, its button allow user to
operate for display control or system characteristic setting
3.3.1. Graphic Data Logger Configuration
The following table indicates the main specification of the Data Logger:
LCD Display
Monochrome
Displayed Information
Each I/P power, O/P power, Operation mode and warning message
Storage Period
5 years
Storage Media
2GB SD card (support up to 32GB)
Data Download
Via B type USB
3.3.2. Features of Graphic Data Logger
Multicolored back light
The backlight of the LCD will be changed according to its status. There are 3 colors of backlight and their
indications are:
Green:
Start-up and normal status
Red:
Fault Status. In this status, Inverter disconnected from grid due to system fault or Inverter.
These faults and failures are defined in “error message table” later on.
Yellow:
Warning Status. Inverter disconnected from grid due to system fault within the past 48 hours,
but Inverter reconnected.