Chapter 4 – Operation
SS2400T/S
4-31
such quickly sent M-codes could "merge" in one code. The barfeeder is able to distinguish
the M-code leading edge only if it does not report the M-code end to the lathe. For this
reason it is recommended to set the parameter #008 to
Static
on new lathes.
In every case the lathe should not begin to send the new M-code in approx. 0.2 s after
termination of the previous M-code. If the barfeeder is not able to distinguish individual M-
codes, it will most probably report the error no.9.
4.10.3.8
#103 – BARFEEDER STROKE
Parameter #103 states a maximum working stroke of the barfeeder flag. The maximum
working stroke of the barfeeder flag must be shorter than the travel done by the flag from the
back limit position to the front limit position. An optimal difference of these two lengths is
approx. 2 to 3 mm.
Usual value of the parameter #103
approx. 1640 mm
4.10.3.9
#108 – MATERIAL SWITCH POSITION (SS2400S)
Parameter #108 states the distance of the material switch B34 from the barfeeder reference
point.
Usual value of the parameter #108
approx. 1576 mm
Use the material switch calibration function for precise setting of the parameter #108, see
Chapter 4.9.5.4.
4.10.3.10
#009 – FACTORY RESET
Using the parameter #009, you can call the function that resets all important parameters, the
Channel Position Table and the jobs table, software options and other information saved in
the memory of the barfeeder.
This function is used in production for initial setting of all important values.
Be especially careful in eventual use of the reset function. Changes made
by the reset function are extensive and irreversible! You can, for example,
destroy all jobs you have saved in the Jobs Table!
#009
Description
No Reset
Reset function is inactive.
Parameters
Reset function saves initial values into all operator and service
parameters and resets the function evaluating successful and failed go to
reference. In move to reference you will have to move the reference
point.
Finally, it restarts the barfeeder's PLC.
Initial values of the parameters
Parameter
SS2400T
SS2400S
#000
Automat Automat
#001
ON ON
#002
Short Short
#003
Stand Still
Stand Still
Summary of Contents for SPACESAVER 2400S
Page 2: ......
Page 8: ...Table of Contents 8 SS2400T S...
Page 17: ...Chapter 1 Description SS2400T S 1 7...
Page 18: ......
Page 75: ...Chapter 5 Maintenance SS2400T S 5 13 5 3 6 WIRING DIAGRAMS...
Page 76: ...Chapter 5 Maintenance 5 14 SS2400T S...
Page 77: ...Chapter 5 Maintenance SS2400T S 5 15...
Page 78: ...Chapter 5 Maintenance 5 16 SS2400T S...
Page 79: ...Chapter 5 Maintenance SS2400T S 5 17...
Page 80: ...Chapter 5 Maintenance 5 18 SS2400T S...
Page 81: ...Chapter 5 Maintenance SS2400T S 5 19...
Page 82: ...Chapter 5 Maintenance 5 20 SS2400T S...
Page 83: ...Chapter 5 Maintenance SS2400T S 5 21...