ACC7200 Air Compressor Controller User Manual Page 56 of 77
8.4
SELECTION OF SENSORS
Table 13 Sensors Selection
No.
Description
Remark
1
Temperature Sensor
0: Not used
1: Custom Res Curve
2: Custom (4-20)mA Curve
3: Custom Volt Curve
4: VDO
5: CURTIS
6: VOLVO-EC
7: DATCON
8: SGX
9: SGD
10: SGH
11: PT100
12: Cu50
13-15 Reserved
Defined resistance’s
range is (0~1) KΩ,
default is Not Used;
Users can select
corresponding curve by
themselves;
If pre-set sensor channel
doesn't support current,
and voltage type, then
curve type item 2 and 3
display “Reserved”.
2
Pressure Sensor
0: Not used
1: Custom Res Curve
2: Custom (4-20)mA Curve
3: Custom Volt Curve
4: VDO 10bar
5: CURTIS
6: VOLVO-EC
7: DATCON 10bar
8: SGX
9: SGD
10: SGH
11 -15 Reserved
Defined resistance’s
range is (0~1)KΩ, default
is Not Used; Users can
select corresponding
curve by themselves;
If pre-set sensor channel
doesn't support current,
and voltage type, then
curve type item 2 and 3
display “Reserved”.
3
Fuel Level Sensor
0: Not used
1: Custom Res Curve
2: Custom (4-20)mA Curve
3: Custom Volt Curve
4: SGD
5: SGH
6: Reserved
7: 0-130Ω
8:10-180Ω
9: 240-33Ω
10: 70-10Ω
11-15 Reserved
Defined resistance’s
range is (0~1)KΩ, default
is Not Used; Users can
select corresponding
curve by themselves;
If pre-set sensor channel
doesn't support current,
and voltage type, then
curve type item 2 and 3
display “Reserved”.