ACC7200 Air Compressor Controller User Manual Page 47 of 77
No.
Item
Range
Default
Description
2: Running time+ Real-time
Clock
5
Maint. Time Due
Timing the set date of the
real-time clock.
—
After ACC7200 using USB, the USB protective rubber cap shall be restored to its original state, so as to achieve
better dust-proof and water-proof effect.
—
Regarding parameter setting on PC software, it isn't needed to input default factory password “01234” if it is not
changed; if it is the first time to do configuration on PC, then it is needed to input module password in password
screen.
—
After correct password is inputted, there is no need to input again within 5 minutes and parameter setting can be
entered directly;
—
Digital input ports cannot be set the same item, otherwise function shall not work correctly; Output ports can be set
the same item.
—
Engine temperature related settings: if it is ordinary engine and engine temperature is needed, engine temperature
related sensor shall be set; choose corresponding digital sensor channel, and the channel can lead to engine temp.
sensor, and engine temperature shall be displayed at this time.
—
Engine oil pressure related settings: if it is ordinary engine and it is needed to use engine oil pressure to judge crank
disconnect, engine oil pressure related sensor shall be set; choose corresponding flexible sensor channel and this
channel can lead to engine oil pressure sensor, engine oil pressure shall be displayed at this time, as one of the
conditions of crank disconnection.